11301: Difference between revisions

From TekWiki
Jump to navigation Jump to search
No edit summary
No edit summary
 
(48 intermediate revisions by 3 users not shown)
Line 1: Line 1:
{{Oscilloscope Sidebar |
{{Oscilloscope Sidebar  
title=Tektronix 11301 |
|manufacturer=Tektronix
summary=400 MHz programmable analog scope |
|series=11000-series scopes
image= Tek 11301a front.JPG |
|model=11301  
caption=Tek 11301   |
|summary=400 MHz programmable analog scope  
introduced=1987 |
|image= Tek 11301a front.JPG  
discontinued=(?) |
|caption=Tek 11301
manuals=
|introduced=1986
* [[Media:070-7178-00.pdf|Tektronix 11301A Service Reference Manual (PDF, OCR)]]
|discontinued=(?)  
* [[Media:061-3380-00.pdf|Tektronix 11301 Preliminary Service Information (PDF, OCR)]]
|designers=
* [[Media:Tek 11301 11302 prelim service.pdf|Tektronix 11301 / 11302 Preliminary Service Information (OCR, PDF)]]
|manuals=
* [[Media:070-6693-00.pdf|Tektronix 11301 and 11302 Incoming Inspection Procedure]]
* [[Media:070-6106-00.pdf|Tektronix 11301 and 11302 Programming Guide]]
* [[Media:070-6106-00(1).pdf|Tektronix 11301 and 11302 User's Reference Manual]] (OCR)
* [[Media:070-6780-00.pdf|Tektronix 11301 Programmable Oscilloscope Service Reference]]
* [[Media:070-7178-00.pdf|Tektronix 11301A Service Reference]] (OCR)
* [[Media:11301A Service with bookmarks.pdf|Tektronix 11301A Service Reference]] (OCR, bookmarks, blank pages removed)
* [[Media:061-3380-00.pdf|Tektronix 11301 Preliminary Service Information]] (OCR)
* [[Media:Tek 11301 11302 prelim service.pdf|Tektronix 11301 / 11302 Preliminary Service Information]] (OCR)
* [[Media:Early Proto11301 11T84.pdf|Photo of 11301 Prototype During Development]]
* [https://archive.org/download/tektronix_11300_Brochure_Egg/tektronix_11300_Brochure_Egg.pdf 11300 Series Product Brochure]
* [[Media:070-7177-00.pdf|Tektronix 11301A and 11302A Functional Test Manual]] (needed)
* [[Media:070-7174-00.pdf|Introducing the 11301A and 11302A]] (needed)
}}
}}
The '''Tektronix 11301''' is a programmable 400 MHz analog oscilloscope that takes up to three
The '''Tektronix 11301''' is a programmable 400 MHz analog oscilloscope that takes up to three
[[11000-series plug-ins]] or (vertical) [[:7000-series plug-ins]].
[[11000-series plug-ins]] or (vertical) [[:7000-series plug-ins]].
Line 18: Line 29:
The sister model [[11302]] is basically identical but has a [[micro-channel plate CRT]] and 500 MHz bandwidth.
The sister model [[11302]] is basically identical but has a [[micro-channel plate CRT]] and 500 MHz bandwidth.


The 11301 has an infrared beam touch screen.
The 11301 has an infrared beam touch screen. There are 10 columns and 14 rows of beams.
There are 10 columns and 14 rows of beams.
 
The 11301 contains a 77 nanosecond delay line.
 
The 11301 and 11302 make use of a [[Patent_US_4677340A|patented]] system for automatically calibrating all the way to the graticule
(i.e., including CRT deflection sensitivity) by optically sensing the position of the beam with respect to the graticule
and applying any necessary correction factors. This is discussed in the patent and also on page 9 of the Handshake article linked
below which states:
<blockquote>
Optical sensors on the CRT bezel sense when the beam crosses the graticule lines to factor this information into the auto cal control signals. As a result, accuracy of the 11300-Series is controlled from the plug-in input connector to the CRT graticule without operator intervention.
</blockquote>


{{BeginSpecs}}
{{BeginSpecs}}
{{Spec | Bandwidth | 400 MHz }}
{{Spec | Bandwidth | 400 MHz }}
{{Spec | Sweep | 5 ns/Div to 500 ms/Div, 1-2-5, &times;10 magnifier <br />(same specs for delayed time base) }}
{{Spec | Sweep | 5 ns/Div to 500 ms/Div, 1−2−5, 10 magnifier <br />(same specs for delayed time base) }}
{{Spec | Triggering | 0.35 Div (int) or 20 mV (ext) to 50 MHz, increasing to 1 Div/150 mV at max. bandwidth}}
{{Spec | Triggering | 0.35 Div (int) or 20 mV (ext) to 50 MHz, increasing to 1 Div/150 mV at max. bandwidth}}
{{Spec | Trigger&nbsp;modes | DC, AC (&gt;50 Hz), HF Reject (&lt; 30 kHz), LF reject (&gt;80 kHz), TV (line or field) }}
{{Spec | Trigger modes | DC, AC (>50 Hz), HF Reject (<30 kHz), LF reject (>80 kHz), TV (line or field) }}
{{Spec | X-Y operation | X from center plugin, bandwidth 3 MHz<br />X-Y phase difference &lt;1&deg; to 1 MHz, &lt;3&deg; to 2 MHz }}
{{Spec | X-Y operation | X from center plugin, bandwidth 3 MHz<br />X-Y phase difference < 1° to 1 MHz, <3° to 2 MHz }}
{{EndSpecs}}
{{EndSpecs}}
tba
 
==Links==
{{Documents|Link=11301}}


==Pictures==
==Pictures==


<gallery>
<gallery>
File:Tek 11301a front.JPG
Tek 11301a front.JPG
Tek 11301 trace.jpg
Tek 11301 trace.jpg
Tek 11301 trace2.jpg
Tek 11301 trace2.jpg
11301 block diag.png
11301 HV parts location.jpg|HV parts location
</gallery>
</gallery>
==Components==
{{Parts|11301}}
{{Parts|11301A}}


[[Category:11000 series mainframes]]
[[Category:11000 series mainframes]]
[[Category:GPIB interface]]
[[Category:GPIB interface]]
[[Category:RS-232 interface]]
[[Category:RS-232 interface]]

Latest revision as of 08:24, 21 March 2024

Manuals – Specifications – Links – Pictures

The Tektronix 11301 is a programmable 400 MHz analog oscilloscope that takes up to three 11000-series plug-ins or (vertical) 7000-series plug-ins. Note, however, that the 7000 series plugins have mechanical interlock preventing them from being installed into an 11K mainframe.

The sister model 11302 is basically identical but has a micro-channel plate CRT and 500 MHz bandwidth.

The 11301 has an infrared beam touch screen. There are 10 columns and 14 rows of beams.

The 11301 contains a 77 nanosecond delay line.

The 11301 and 11302 make use of a patented system for automatically calibrating all the way to the graticule (i.e., including CRT deflection sensitivity) by optically sensing the position of the beam with respect to the graticule and applying any necessary correction factors. This is discussed in the patent and also on page 9 of the Handshake article linked below which states:

Optical sensors on the CRT bezel sense when the beam crosses the graticule lines to factor this information into the auto cal control signals. As a result, accuracy of the 11300-Series is controlled from the plug-in input connector to the CRT graticule without operator intervention.

Key Specifications

Bandwidth 400 MHz
Sweep 5 ns/Div to 500 ms/Div, 1−2−5, 10 magnifier
(same specs for delayed time base)
Triggering 0.35 Div (int) or 20 mV (ext) to 50 MHz, increasing to 1 Div/150 mV at max. bandwidth
Trigger modes DC, AC (>50 Hz), HF Reject (<30 kHz), LF reject (>80 kHz), TV (line or field)
X-Y operation X from center plugin, bandwidth 3 MHz
X-Y phase difference < 1° to 1 MHz, <3° to 2 MHz

Links

Documents Referencing 11301

Document Class Title Authors Year Links
Handshake 1986-1987 Winter.pdf Article 11300-Series extends the usefulness of analog scopes Dale Aufrecht 1986

Pictures

Components

Some Parts Used in the 11301

Part Part Number(s) Class Description Used in
165-2053-00 165-2053-00 Hybrid integrated circuit vertical amplifier 11301 11302
M229 Monolithic integrated circuit input/output 11301 11302
M414 Monolithic integrated circuit counter 11301 11302


Some Parts Used in the 11301A