V<sub>C</sub> is controlled by a ten-turn potentiometer and can vary from −5 V to +5 V (0.5 V on the 5 V/div to 20 V/div ranges).   
V<sub>C</sub> is controlled by a ten-turn potentiometer and can vary from −5 V to +5 V (0.5 V on the 5 V/div to 20 V/div ranges).   
==Internals==
The 1A5 is solid-state except for a pair of [[7586|7586 nuvistors]] used in the upper half of a cascode in the second amplifier stage.
The attenuator switching is mechanically complex.  A gear mechanism drives the input attenuator switch (under the internal cover) selecting attenuators ×1000 (20 V/div to 5 V/div), ×100 (2 V/div to 500 mV/div), ×10 (200 mv/div to 50 mV/Div) or no attenuators (20 mV/Div to 1 mV/div).
Additionally, in the 500 mV/div and 50 mV/div positions, the operator can pull the V/Div knob outward when switching to one of the next two more sensitive ranges, in which case the higher attenuator (and higher input and comparison voltage range) remains in place.