  passive 134 7A14 Max. current Cable Notes
P6016 230/850 Hz – 20 MHz 50 Hz – 17 MHz ? 15 Ap-p
max. 0.5 ADC
 m 125 turns
P6019 120/450 Hz – 60 MHz 12 Hz – 40 MHz ? 15 Ap-p  m 125 turns
P6020 775/6500 Hz – 200 MHz 50 Hz – 70 MHz ? 6 Ap-p  m  50 turns
P6021 120/450 Hz – 70 MHz 12 Hz – 70 MHz 25 Hz – 55 MHz 15 Ap-p  m 125 turns
P6022 935/8500 Hz – 200 MHz 100 Hz – 70 MHz 250 Hz – 120 MHz 6 Ap-p  m  50 turns
P6040/CT-1 35 kHz – 1 GHz  m
P6041/CT-2 1.2 kHz – 200 MHz  m
CT-6 250 kHz – 1.5(2) GHz 120 mARMS cont., 6 A peak  m
  • A621 – clamp-on AC current probe for multimeters and LF scopes (e.g. THM500) – 5 Hz to 50 kHz, max. 2 kA peak
  • CT-4 – (passive) extends A6302/A6302XL/A6312/TCP202/P6021 by 20:1 or 1000:1, up to 2 kA (peak 20 kA).
  • CT-5 – (passive) extends A6302/P6021 by a 1000:1, up to 5000 A/div.
  • TRCP0300 – 300 A Rogowski coil, 9 Hz - 30 MHz
  • TRCP0600 – 600 A Rogowski coil, 12 Hz - 30 MHz
  • TRCP3000 – 3 kA Rogowski coil, 1 Hz - 16 MHz

DC capable current probes

AM5xx/11A16

  AM503 AM503A AM503B AM5030 11A16 CT-4 Max. current Cable
A6302/P6302 50 MHz 50 MHz 50 MHz 50 MHz 50 MHz
10.5 A
20 A (DC + peak AC)
50 A peak, ≤100 A · μs
2 m
A6302XL 17 MHz 17 MHz 20 A (DC + peak AC)
50 A peak, ≤100 A · μs
8 m
A6303/P6303 15 MHz 15 MHz 15 MHz 15 MHz 15 MHz 100 A (DC + peak AC)
500 A peak, ≤10 kA · μs
2 m
A6303XL 10 MHz 10 MHz 100 A (DC + peak AC)
500 A peak, ≤10 kA · μs
8 m
A6304XL 2 MHz 2 MHz 500 A (DC + peak AC)
700 A peak, ≤400 kA · μs
8 m
A6312 100 MHz 80 MHz 100 MHz 100 MHz 20 A (DC + peak AC)
50 A peak, ≤100 A · μs
2 m

Other

  • P6042 – DC to 50 MHz, Max. 10 A DC + peak AC
  • A622 – clamp-on AC/DC current probe for multimeters and LF scopes (e.g. THM500) – DC to 100 kHz, max. 70 A peak

Tekprobe BNC

TekVPI