The '''Tektronix P6000''' is a 30 MHz, ×10 passive voltage probe designed for use with oscilloscopes that have a 1 MΩ // 20 to 50 pF input impedance and a [[UHF connector]].
The '''Tektronix P6000''' is a 30 MHz, ×10 passive voltage probe designed for use with oscilloscopes that have a 1 MΩ // 20 to 50 pF input impedance and a [[UHF connector]].
The [[P6003]] is a variant of the [[P6000]] that has a [[BNC connector]] instead of a UHF connector.
The [[P6003]] is a variant of the [[P6000]] that has a [[BNC connector]] instead of a UHF connector.
The compensation is done by changing the length of the probe body itself, which is achieved by turning the front part after loosening the finger stop which also serves as a twist-lock.


{{BeginSpecs}}
{{BeginSpecs}}
Line 29: Line 30:
{{EndSpecs}}
{{EndSpecs}}


 
==Pictures==
<gallery>
Tektronix_P6000_Probe_2.jpg
Tektronix_P6000_probe.jpg
Tektronix_P6000_head.jpg
Tektronix_P6000_head_2.jpg
Tektronix P6000 compensation.JPG
Tektronix_P6000_UHF_connector.jpg
</gallery>


[[Category:1 MΩ Oscilloscope probes]]
[[Category:1 MΩ Oscilloscope probes]]
[[Category:6-32 probes]]
[[Category:6-32 probes]]

Latest revision as of 00:13, 4 July 2023

Tektronix P6000
30 MHz ×10 Passive Probe
Tektronix P6000

Compatible with 1 MΩ scope inputs

Produced from (?) to (?)

Manuals


Manuals – Specifications – Links – Pictures

The Tektronix P6000 is a 30 MHz, ×10 passive voltage probe designed for use with oscilloscopes that have a 1 MΩ // 20 to 50 pF input impedance and a UHF connector. The P6003 is a variant of the P6000 that has a BNC connector instead of a UHF connector. The compensation is done by changing the length of the probe body itself, which is achieved by turning the front part after loosening the finger stop which also serves as a twist-lock.

Key Specifications

Input impedance 10 MΩ // 11.5–14.5 pF
Compensation range 1 MΩ // 20–50 pF
Maximum input 1200 V DC or AC peak
Cable
  • 3.5 feet, part number 010-0020-00
  • 6 feet, part number 010-0030-00
  • 9 feet, part number 010-0035-00
  • 12 feet, part number 010-0041-00