TDS3034: Difference between revisions

From TekWiki
Jump to navigation Jump to search
No edit summary
(Link to USB floppy emulator instructions)
 
(12 intermediate revisions by 3 users not shown)
Line 1: Line 1:
{{Oscilloscope Sidebar |
{{Oscilloscope Sidebar |manufacturer=Tektronix |series=TDS series scopes|designers= |
title=Tektronix TDS3034 |
model= TDS3034 |
summary=Digital Storage 300 MHz 2-channel scope |
summary=Digital Storage 300 MHz 4-channel scope |
image=TDS3032.jpg |
image=TDS3034_Waveform_image.jpg |
caption=Tektronix TDS3034 |
caption=Tektronix TDS3034 |
introduced=1998 |
introduced=1998 |
discontinued=? |
discontinued=(?) |
manuals=
manuals=
* [[Media: 071-0274-01.pdf| 071-0274-01 TDS3000 Series User Manual]] (1.4 MB, PDF)
* [[Media: 071-0274-01.pdf| 071-0274-01 TDS3000 Series User Manual]] (1.4 MB, PDF)
Line 11: Line 11:
* [[Media: TDS3000C Series Datasheet.pdf| TDS3000C Series Datasheet]] (786 KB, PDF)
* [[Media: TDS3000C Series Datasheet.pdf| TDS3000C Series Datasheet]] (786 KB, PDF)
}}
}}
The '''Tektronix TDS3034''' is a four-channel, 300 MHz, 2.5 GS/s digital phosphor oscilloscope with a TFT color screen.  This series of scopes combines 3,600 wfms/s continuous waveform capture rate and real-time intensity grading so you can see the problem and solve it.  This series of scope can run without AC power for up to three hours when TDS3BATC rechargeable lithium ion battery pack is installed.


The '''Tektronix TDS3034''' is a four-channel, 300 MHz, 2.5 GS/s digital phosphor oscilloscope with a TFT color screen.  This series of scopes combines 3,600 wfms/s continuous waveform capture rate and real-time intensity grading so you can see the problem and solve it.  An External trigger input, Ethernet port, and USB port round out base inputs and outputs until the optional TDS3GV Communication Module is added which adds GPIB, RS-232-C, and VGA video ports.  It can run without AC power for up to three hours when TDS3BATC rechargeable lithium ion battery pack is installed.
Besides the channel inputs and the EXT TRIG input (two-channel models only), a [[Floppy]] Disk Drive and Centronics [[Parallel printer interface]] was available on the original and B version of this oscilloscope series until the C version which replaced the [[Floppy]] with a [[USB connector]] drive, and [[Parallel printer interface]] was removed altogetherOptional Communication Modules were available such as the TDS3GM (GPIB/RS-232), TDS3VM ([[VGA Connector]]/[[RS-232 interface]]), TDS3EM ([[Ethernet]]/[[RS-232 interface]]), TDS3GV ([[GPIB]], [[RS-232 interface]]/[[VGA Connector]]), and the TDS3SDI 601 Serial/Digital Video Module.
 
Up to four Applications modules can be added to the upper right corner to transform the oscilloscope into a specialized instrument for limit testing, telecommunications mask testing, and video troubleshootingThese include the TDS3AAM Advanced Analysis Module, TDS3LIM Limit Testing Module, TDS3TMT Telecommunications Mask Testing Module, TDS3VID Extended Video Analysis Module, and TDS3SDI 601 Serial/Digital Video Module.  The TDS3014, TDS3034, and TDS3054 also had available the TDS3FFT FFT Analysis and Measurement, and TDS3TRG Advanced Triggering modules.  (NOTE: The TDS3FFT module is no longer available so Tektronix now provides the FFT capability standard with SW V.3.39)
 
Easy access to the MATH MENU button provides waveform adjustments (CH1-CH2, CH2-CH1, CH1+CH2) along with FFT (spectrum, harmonics, distortion, noise, impulse, vibration) measurements.  Measurements can also be performed for time (frequency) and voltage (amplitude).  Repetitive signals can be captured and averaged to remove noise, or captured as a single-shot signal.
 
Acquisition Modes include DPO, Peak Detect, WaveAlert, Sample, Average, Envelop, and Single Sequence.
 
Triggering of signal capturing is available through a comprehensive TRIG MENU providing Edge (rising or falling), Video (NTSC, PAL, SECAM), Extended Video (specific lines in broadcast or non-broadcast standard, and analog HDTV formats), Pulse Width (or Glitch) triggering, Runt, Slew Rate, Pattern (AND, OR, NAND, NOR), State (logic state), Comm (pulse), or Alternate.  Coupling selections are AC, DC, Noise Reject, HF Reject, LF Reject.


Up to four Applications modules can be added into the small door in the upper right corner to transform the oscilloscope into a specialized instrument for limit testing, telecommunications mask testing, and video troubleshooting.  The [[TDS3AAM]] Advanced Analysis Module, TDS3LIM Limit Testing Module, TDS3TMT Telecommunications Mask Testing Module, and the TDS3VID Extended Video Analysis Module were available for added functionality.  The TDS3TRG (Advanced Trigger) and TDS3FFT (Fast Fourier Transform) application modules were available in the original model of this oscilloscope series but made standard on the B and higher versions. 


There are many options for signal acquisition, measurement, and analysis.  The Getting Started section of the User Manual is a great place to become familiar with the many functions available in the use of this sophisticated instrument.


{{BeginSpecs}}
{{BeginSpecs}}
Line 32: Line 27:
{{Spec | Waveform Measurements| 25 Automatic, waveform add, subtract, divide, and multiply math functions, Fast Fourier Transform (FFT), Advanced Math (Integrate, Differentiate, Define extensive algebraic expressions, math functions, scalars, user adjustable variables) }}
{{Spec | Waveform Measurements| 25 Automatic, waveform add, subtract, divide, and multiply math functions, Fast Fourier Transform (FFT), Advanced Math (Integrate, Differentiate, Define extensive algebraic expressions, math functions, scalars, user adjustable variables) }}
{{EndSpecs}}
{{EndSpecs}}
==Links==
* [https://github.com/andrewpono/TDS3000-Series-Gotek-FlashFloppy Instructions on replacing the floppy drive with a USB emulator]


==Pictures==
==Pictures==
Line 37: Line 36:
TDS3034_Waveform_image.jpg
TDS3034_Waveform_image.jpg
TDS3034_2.jpg
TDS3034_2.jpg
TDS3034_3 jpg
TDS3034_3.jpg
TDS3034_4 jpg
TDS3034_4.jpg
</gallery>
</gallery>




[[Category:TDS3000 series scopes]]
[[Category:TDS3000 series scopes]]

Latest revision as of 08:42, 17 October 2023

Tektronix TDS3034
Digital Storage 300 MHz 4-channel scope
Tektronix TDS3034

Produced from 1998 to (?)

Manuals
(All manuals in PDF format unless noted otherwise)
Manuals – Specifications – Links – Pictures

The Tektronix TDS3034 is a four-channel, 300 MHz, 2.5 GS/s digital phosphor oscilloscope with a TFT color screen. This series of scopes combines 3,600 wfms/s continuous waveform capture rate and real-time intensity grading so you can see the problem and solve it. This series of scope can run without AC power for up to three hours when TDS3BATC rechargeable lithium ion battery pack is installed.

Besides the channel inputs and the EXT TRIG input (two-channel models only), a Floppy Disk Drive and Centronics Parallel printer interface was available on the original and B version of this oscilloscope series until the C version which replaced the Floppy with a USB connector drive, and Parallel printer interface was removed altogether. Optional Communication Modules were available such as the TDS3GM (GPIB/RS-232), TDS3VM (VGA Connector/RS-232 interface), TDS3EM (Ethernet/RS-232 interface), TDS3GV (GPIB, RS-232 interface/VGA Connector), and the TDS3SDI 601 Serial/Digital Video Module.

Up to four Applications modules can be added into the small door in the upper right corner to transform the oscilloscope into a specialized instrument for limit testing, telecommunications mask testing, and video troubleshooting. The TDS3AAM Advanced Analysis Module, TDS3LIM Limit Testing Module, TDS3TMT Telecommunications Mask Testing Module, and the TDS3VID Extended Video Analysis Module were available for added functionality. The TDS3TRG (Advanced Trigger) and TDS3FFT (Fast Fourier Transform) application modules were available in the original model of this oscilloscope series but made standard on the B and higher versions.

There are many options for signal acquisition, measurement, and analysis. The Getting Started section of the User Manual is a great place to become familiar with the many functions available in the use of this sophisticated instrument.

Key Specifications

Bandwidth and Channels 300 MHz; Analog Bandwidth Limit switchable between 20 MHz and 150 MHz; 4 Channels
Vertical Sensitivity 1 mV to 10 V/div (1 MΩ), 1 mV to 1 V/div (50 Ω)
Time Base Range 2 ns to 10 s/div
Sample Rate 2.5 GS/s on each channel
Record Length 10 K points
Waveform Measurements 25 Automatic, waveform add, subtract, divide, and multiply math functions, Fast Fourier Transform (FFT), Advanced Math (Integrate, Differentiate, Define extensive algebraic expressions, math functions, scalars, user adjustable variables)

Links

Pictures