067-0587-00: Difference between revisions
Jump to navigation
Jump to search
(created its own page separating from 067-0587-01) Tag: Removed redirect |
m (Capitolize sidebar summary & add 7000 Series) |
||
(2 intermediate revisions by 2 users not shown) | |||
Line 2: | Line 2: | ||
|manufacturer=Tektronix | |manufacturer=Tektronix | ||
|type=067-0587-00 | |type=067-0587-00 | ||
|summary= | |summary=7000 Series Calibration Fixture | ||
|image=Tektronix_067-0587-00.JPG | |image=Tektronix_067-0587-00.JPG | ||
|caption=067-0587-00 | |caption=067-0587-00 | ||
Line 9: | Line 9: | ||
|discontinued=(?) | |discontinued=(?) | ||
|manuals= | |manuals= | ||
missing | * missing, please add [[Category:Manual needed]] | ||
}} | }} | ||
The '''Tektronix 067-0587-00 Calibration Fixture''' is designed to standardize the | The '''Tektronix 067-0587-00 Calibration Fixture''' is designed to standardize the | ||
horizontal and vertical deflection factors of 7000 series mainframes. | horizontal and vertical deflection factors of 7000 series mainframes. | ||
It provides a uniform step calibrated deflection factor, a fast risetime | It provides a uniform step calibrated deflection factor, a fast risetime step response function and a leveling circuit to measure the frequency response for both the | ||
step response function and a leveling circuit to measure the | |||
vertical and trigger systems. It is the predecessor of the [[067-0587-01]] and [[067-0587-02]] and the slowest of the three variants, also lacking the common mode testing feature. | vertical and trigger systems. It is the predecessor of the [[067-0587-01]] and [[067-0587-02]] and the slowest of the three variants, also lacking the common mode testing feature. | ||
{{BeginSpecs}} | {{BeginSpecs}} | ||
{{Spec | Rise time | ? }} | {{Spec | Rise time | ? }} | ||
{{Spec | Bandwidth | | {{Spec | Bandwidth | 250 MHz }} | ||
{{EndSpecs}} | {{EndSpecs}} | ||
==Pictures== | ==Pictures== | ||
Line 31: | Line 28: | ||
[[Category:7000 series test and calibration plugins]] | [[Category:7000 series test and calibration plugins]] | ||
[[Category:Fiche Scan Wanted]] | [[Category:Fiche Scan Wanted]] |
Latest revision as of 20:06, 15 November 2023
The Tektronix 067-0587-00 Calibration Fixture is designed to standardize the horizontal and vertical deflection factors of 7000 series mainframes. It provides a uniform step calibrated deflection factor, a fast risetime step response function and a leveling circuit to measure the frequency response for both the vertical and trigger systems. It is the predecessor of the 067-0587-01 and 067-0587-02 and the slowest of the three variants, also lacking the common mode testing feature.
Key Specifications
Rise time | ? |
---|---|
Bandwidth | 250 MHz |
Pictures
-
067-0587-00 front
-
067-0587-00