EIP 101A: Difference between revisions

From TekWiki
Jump to navigation Jump to search
No edit summary
No edit summary
 
(24 intermediate revisions by 2 users not shown)
Line 1: Line 1:
{{Plugin Sidebar 2|
{{Plugin Sidebar  
title=EIP 101A |
|manufacturer=EIP
summary=Microwave Spectrum Analyzer plug-in |
|series=500-series scopes
image=EIP101A_front_ISO.jpg |
|type=101A
caption=EIP 101B Microwave Spectrum Analyzer plug-in |
|summary=Microwave Spectrum Analyzer plug-in  
series=[[500-series scopes]] |
|image=EIP101A_faceplate.jpg  
introduced=(?) |
|caption=EIP 101A Microwave Spectrum Analyzer plug-in  
discontinued=(?) |
|introduced=(?)  
manuals=
|discontinued=(?)  
* ''please add'' [[Category:Manual needed]]  
|designers=
|manuals=
* [[Media:EIP 101A_201A_Ops_Svc.pdf|EIP 101A Operation and Instruction Manual w/schematics]]
}}
}}
The '''EIP 101A''' is a Spectrum Analyzer plug-in, designed to work in all Tektronix oscilloscope mainframes which accept letter-type plug-ins. Used in the 201A power supply unit, it works together with all analog oscilloscopes. It covers the frequency range of 0.7-15GHz in one single band (tuned YIG bandpass design)..
The '''EIP 101A''' is a receiver-type Spectrum Analyzer plug-in, designed to work in all Tektronix oscilloscope mainframes which accept letter-type plug-ins.  
Used in the 201A power supply unit, it works together with all analog oscilloscopes.  
It covers the frequency range of 0.7 - 15 GHz in one single band and comprises a three-resonator YIG preselector.


 
{{BeginSpecs}}
 
{{Spec | Frequency Range | 1 − 12.4 GHz (useable 0.7 − 15.7 GHz)<sup>*</sup>}}
{{MissingSpecs}}
{{Spec | Dial Frequency Accuracy | 10 MHz ±3%<sup>**</sup>}}
 
{{Spec | Video Bandwidth | 1 kHz, 100 kHz, 3 MHz }}
==Links==
{{Spec | Frequency Response | ±2 dB typical, ±4 dB maximum  }}
{{Spec | Calibrated Dispersion  | 0 − 11.4 GHz (useable 0 - 15.0 GHz)  }}
{{Spec | Dispersion Resettability  | 10 MHz  }}
{{Spec | Dispersion Dial Accuracy  | 10 MHz or ±0.5% whichever is greater  }}
{{Spec | Preselection  | 3 Resonator YIG filter, nominal 3 dB bandwidth 15 MHz, straight thru leakage >60 dB down, tracking spurious typically >45 dB down<sup>***</sup> }}
{{Spec | Resolution  | 15 MHz typ. }}
{{Spec | Image Rejection | Generates no image signals  }}
{{Spec | Intermod Rejection  | Intermod signals are reduced by the preselector selectivity over conventional microwave diode response  }}
{{Spec | Sensitivity | −45 dBm min. (1 kHz bandwidth)  | }}
{{Spec | Max. Input Power  | +20 dBm  }}
{{Spec | Limiting Level | 0.7 − 1.0 GHz -20 dBm typ., 1.0 − 1.2 GHz >+5 dBm, 1.2 − 15.7 GHz >+10 dBm (all at 2 dB compression) }}
{{Spec | Log Accuracy | ±1 dB typ. (<1 mW input)  }}
{{Spec | Variable Vertical Log Scale (dB/cm)  | Variable and calibratable with internal calibrate signal over the range of 2 dB/cm to 20 dB/cm  }}
{{Spec | Log Video output  | 0.02 Volts/dB typ. }}
{{Spec | Sweep Rate  | 1, 10, 30 Hz  }}
{{EndSpecs}}
:<sup>*</sup> Usable frequency coverage is limited by the center frequency dial indicator with the unit set on a center frequency of 12 GHz and dispersion set for 15 GHz, most units will display signals as high as 18 GHz.
:<sup>**</sup> If setting is always approached from 700 MHz, if not, add 5 - 15 MHz for hysteresis.
:<sup>***</sup>Tracking spurious is a second pass band response, always located a fixed number of MHz (approximately 200 MHz) above the normal preselector response.


==Pictures==
==Pictures==
<gallery>
<gallery>
EIP101A_front_ISO.jpg
EIP101A_front_ISO.jpg
EIP101A_back_ISO.jpg
EIP101A_bottom_front_plate.jpg
EIP101A_bottom_view.jpg
EIP101A_DC_block_and_Detector.jpg
EIP101A_gearbox.jpg
EIP101A_left side.jpg
EIP101A_pcbs.jpg
EIP101A_right_side.jpg
EIP101A_top.jpg
Eip 101a 1.jpeg
</gallery>
</gallery>


[[Category:500 series plugins]]
[[Category:500 series plugins]]
[[Category:Spectrum analyzers]]
[[Category:Spectrum analyzers]]

Latest revision as of 12:25, 9 January 2024

EIP 101A
Microwave Spectrum Analyzer plug-in
EIP 101A Microwave Spectrum Analyzer plug-in

Compatible with 500-series scopes

Produced from (?) to (?)

Manuals
(All manuals in PDF format unless noted otherwise)
Manuals – Specifications – Links – Pictures

The EIP 101A is a receiver-type Spectrum Analyzer plug-in, designed to work in all Tektronix oscilloscope mainframes which accept letter-type plug-ins. Used in the 201A power supply unit, it works together with all analog oscilloscopes. It covers the frequency range of 0.7 - 15 GHz in one single band and comprises a three-resonator YIG preselector.

Key Specifications

Frequency Range 1 − 12.4 GHz (useable 0.7 − 15.7 GHz)*
Dial Frequency Accuracy 10 MHz ±3%**
Video Bandwidth 1 kHz, 100 kHz, 3 MHz
Frequency Response ±2 dB typical, ±4 dB maximum
Calibrated Dispersion 0 − 11.4 GHz (useable 0 - 15.0 GHz)
Dispersion Resettability 10 MHz
Dispersion Dial Accuracy 10 MHz or ±0.5% whichever is greater
Preselection 3 Resonator YIG filter, nominal 3 dB bandwidth 15 MHz, straight thru leakage >60 dB down, tracking spurious typically >45 dB down***
Resolution 15 MHz typ.
Image Rejection Generates no image signals
Intermod Rejection Intermod signals are reduced by the preselector selectivity over conventional microwave diode response
Sensitivity −45 dBm min. (1 kHz bandwidth)
Max. Input Power +20 dBm
Limiting Level 0.7 − 1.0 GHz -20 dBm typ., 1.0 − 1.2 GHz >+5 dBm, 1.2 − 15.7 GHz >+10 dBm (all at 2 dB compression)
Log Accuracy ±1 dB typ. (<1 mW input)
Variable Vertical Log Scale (dB/cm) Variable and calibratable with internal calibrate signal over the range of 2 dB/cm to 20 dB/cm
Log Video output 0.02 Volts/dB typ.
Sweep Rate 1, 10, 30 Hz
* Usable frequency coverage is limited by the center frequency dial indicator with the unit set on a center frequency of 12 GHz and dispersion set for 15 GHz, most units will display signals as high as 18 GHz.
** If setting is always approached from 700 MHz, if not, add 5 - 15 MHz for hysteresis.
***Tracking spurious is a second pass band response, always located a fixed number of MHz (approximately 200 MHz) above the normal preselector response.

Pictures