1,989
edits
mNo edit summary |
No edit summary |
||
(13 intermediate revisions by 4 users not shown) | |||
Line 1: | Line 1: | ||
{{TM5000 | mfg=Tektronix | type=DM5120 | function=programmable 6½-digit multimeter | class=multimeter | image=Tek_dm5120_5_straight.jpg | introduced=1989 | discontinued=1991 | | {{TM5000 | mfg=Tektronix | type=DM5120 | function=programmable 6½-digit multimeter | class=multimeter | image=Tek_dm5120_5_straight.jpg | introduced=1989 | discontinued=1991 | | ||
manuals= | designers= |manuals= | ||
* [[Media:070-7240-00.pdf|DM5120/DM5520 DM5120/5520 Instruction]]<br /><small>[[Media:070-7240-00_2.pdf|Alternate Copy]]</small> | |||
* [[Media:070-7319-00.pdf|DM5120/DM5520 DM5120/5520 Service]]<br /><small>[[Media:070-7319-00_2.pdf|Alternate Copy 1]] / [[Media:070-7319-00_3.pdf|Alternate Copy 2]]</small> | |||
(all with schematics but missing most of the parts list) | |||
'''Firmware''' | |||
* [[Media:5120-800_v1.0.bin|5120-800 V1.0]] | |||
'''Calibration Backup''' | |||
* [ | * [[Media:5120cal.bin|5120cal.bin]] | ||
* [ | |||
}} | }} | ||
The '''DM5520''' is a standalone version, i.e. a DM5120 in a dedicated mainframe | The '''DM5520''' is a standalone version, i.e. a DM5120 in a dedicated, fan-less, mainframe based on the [[TM503B]]. | ||
{{BeginSpecs}} | {{BeginSpecs}} | ||
Line 26: | Line 24: | ||
{{Spec | Input Impedance (AC Volts)| 1 MΩ // 120 pF }} | {{Spec | Input Impedance (AC Volts)| 1 MΩ // 120 pF }} | ||
{{Spec | Current ranges | 300 μA to 3 A in decade steps, DC or AC }} | {{Spec | Current ranges | 300 μA to 3 A in decade steps, DC or AC }} | ||
{{Spec | Resistance ranges | 300 Ω to 300 MΩ in decade steps, 4-wire mode available in | {{Spec | Resistance ranges | 300 Ω to 300 MΩ in decade steps, 4-wire mode available in 300 Ω to 30 kΩ ranges }} | ||
{{Spec | Features | | {{Spec | Features | | ||
* True RMS | * True RMS measurement (crest factor ≤3:1) | ||
* Calibration may be done manually through the front panel or via the [[GPIB interface]]. | * Calibration may be done manually through the front panel or via the [[GPIB interface]]. | ||
}} | }} | ||
Line 34: | Line 32: | ||
==Internals== | ==Internals== | ||
The DM5120 shares its analog section design with the Keithley 196, minus the front/rear switch. | The DM5120 shares its analog section design with the [[Keithley 196]], minus the front/rear switch. | ||
The instrument's internal voltage reference is based on the LM399. | The instrument's internal voltage reference is based on the LM399. | ||
Line 47: | Line 45: | ||
</gallery> | </gallery> | ||
==Components== | |||
{{Parts|DM5120}} | |||
{{Parts|DM5220}} | |||
[[Category:GPIB interface]] | [[Category:GPIB interface]] |