P6460: Difference between revisions

From TekWiki
Jump to navigation Jump to search
No edit summary
No edit summary
 
(13 intermediate revisions by 6 users not shown)
Line 1: Line 1:
[[File:P6460.JPG|thimb|300px|right]]
{{Probe Sidebar
The '''Tektronix P6460''' Data Acquisition Probe can be used with [[DAS9200]], [[91A24]], [[91AE24]], [[1240D1]], or [[1240D2]] Logic Analyzers.  
|manufacturer=Tektronix
|model=P6460
|summary=Data acquisition probe
|for=DAS9200
|image=P6460.JPG
|caption=Tektronix P6460
|introduced=(?)
|discontinued=(?)
|manuals=
* [[Media:070-4345-00.pdf|P6460 Instruction Manual 070-4345-00]] (OCR)
* [[Media:070-4540-00.pdf|P6460 Service manual addendum 070-4540-00]] (P6450, 91A24 and 91AE24)
* [[Media:Tek p6460 missing first two pages no ocr.pdf|P6460 Instruction Manual, July 1986 Update]] (incomplete, OCR)
}}
The '''Tektronix P6460''' Data Acquisition Probe may be used with [[DAS9100]], [[91A24]], [[91AE24]], [[1240D1]], or [[1240D2]] Logic Analyzers. It may also be used with and is required for the [[DP100]] Digital Video Probe plug-in used in the TM500 mainframes. It provides 8 data channels plus one qualifier and one clock channel.


The P6460 uses the [[P64xx input leads|P64xx-family 10-wire input lead harnesses]] with 0.2" connectors.  Is also possible to use standard jumper wires with pins, sockets or clips on the other end for connecting inputs.
The P6460 uses the [[P64xx input leads|P64xx-family 10-wire input lead harnesses]] with 0.2" connectors.  Is also possible to use standard jumper wires with pins, sockets or clips on the other end for connecting inputs.


{{MissingSpecs}}
{{BeginSpecs}}
==Instructions==
{{Spec | Maximum Clock Frequency| ?}}
* [[Media:070-4345-00.pdf | P6460 Instructions]]
{{Spec | Data channel Bandwidth| 100 MHz}}
* [[Media:070-4345-00(diagram).pdf | P6460 Diagram and schematic]]
{{Spec | Minimum Pulse Width | 4 ns}}
{{Spec | Input Signal Level|-40 V to +10 V above threshold (+30 V for RS232)}}
{{Spec | Threshold Voltage| provided from Logic Analyzer}}
{{Spec | Input Capacitance| 5 pF}}
{{Spec | Non-destructive Input Voltage Range| ±40 V}}
{{Spec | Maximum Voltage between any two Inputs| ±60 V}}
{{EndSpecs}}
 
==Links==
==Links==
* [http://www.barrytech.com/tektronix/probes/tekp6460.html P6460 @ barrytech.com]
* [http://www.barrytech.com/tektronix/probes/tekp6460.html P6460 @ barrytech.com]
==Pictures==
==Pictures==
<gallery>
<gallery>
Tek das9100 probes.jpg
Tek das9100 probes.jpg
Tek 6460 1.jpg
Tek 6460 2.jpg
Tek 6460 3.jpg
Tek 6460 4.jpg
Tek 6460 5.jpg
Tek 6460 6.jpg
Tek 6460 7.jpg
Tek 6460 8.jpg
</gallery>
</gallery>


[[Category:Logic analyzer probes]]
[[Category:Logic analyzer probes]]

Latest revision as of 15:20, 18 August 2024

Tektronix P6460
Data acquisition probe
Tektronix P6460

Compatible with DAS9200

Produced from (?) to (?)

Manuals


Manuals – Specifications – Links – Pictures

The Tektronix P6460 Data Acquisition Probe may be used with DAS9100, 91A24, 91AE24, 1240D1, or 1240D2 Logic Analyzers. It may also be used with and is required for the DP100 Digital Video Probe plug-in used in the TM500 mainframes. It provides 8 data channels plus one qualifier and one clock channel.

The P6460 uses the P64xx-family 10-wire input lead harnesses with 0.2" connectors. Is also possible to use standard jumper wires with pins, sockets or clips on the other end for connecting inputs.

Key Specifications

Maximum Clock Frequency ?
Data channel Bandwidth 100 MHz
Minimum Pulse Width 4 ns
Input Signal Level -40 V to +10 V above threshold (+30 V for RS232)
Threshold Voltage provided from Logic Analyzer
Input Capacitance 5 pF
Non-destructive Input Voltage Range ±40 V
Maximum Voltage between any two Inputs ±60 V

Links

Pictures