TDS220: Difference between revisions
Jump to navigation
Jump to search
No edit summary |
Jaredcabot (talk | contribs) (Added TDS200 recall document) |
||
(18 intermediate revisions by 3 users not shown) | |||
Line 1: | Line 1: | ||
{{Oscilloscope Sidebar| | {{Oscilloscope Sidebar | ||
|manufacturer=Tektronix | |||
image=Tek tds220 1.jpg| | |series=TDS series scopes | ||
caption=Tektronix TDS220 | | |model=TDS220 | ||
introduced=1997 | | |summary=100 MHz, 1 GS/s portable digital scope | ||
discontinued=(?) | | |image=Tek tds220 1.jpg | ||
|caption=Tektronix TDS220 | |||
|introduced=1997 | |||
manuals= | |discontinued=(?) | ||
* [ | |designers= | ||
* [ | |manuals= | ||
* [[Media:061-4231-02.pdf|TDS200 Series Release Notes 061-4231-02]] | |||
* [[Media:063-2644-02.pdf|TDS200/1000/2000 Series Extension Module Installation Manual 063-2644-02]] | |||
* [[Media:070-9565-04.pdf|TDS200-Series Extension Modules Instruction Manual 070-9565-04]] | |||
* [[Media:071-0398-03.pdf|TDS200 Series User Manual 071-0398-03]] | |||
* [[Media:071-0409-01.pdf|TDS200 Extension Modules Manual 071-0409-01]] | |||
* [[Media:071-0492-03.pdf|TDS200 Series Service Manual 071-0492-03]] | |||
* [[Media:071-0493-01.pdf|TDS200 Series Programmers Manual 071-0493-01]] | |||
* [[Media:071-1075-03.pdf|TDS200/1000/2000 Series Programmer Manual 071-1075-03]] | |||
* [[Media:071-1075-04.pdf|TDS200/1000/2000 Series Programmer Manual 071-1075-04]] | |||
* [[Media:071-1857-00.pdf|TDS200/1000/2000 Series Memory Erasure and Parts List Manual 017-1857-00]] | |||
* [[Media:077-0444-01.pdf|TDS200/1000/2000 Series Programmer Manual 077-0444-01]] | |||
* [[Media:SUP40-003c.pdf|TDS210/220 Service Update Plan 40-003c - Safety Recall Details]] | |||
* Schematics needed | * Schematics needed | ||
}} | }} | ||
The '''Tektronix TDS220''' is a portable two-channel digital scope with 1 GS/s sampling rate and 100 MHz bandwidth. | The '''Tektronix TDS220''' is a portable two-channel digital scope with 1 GS/s sampling rate and 100 MHz bandwidth. | ||
Sister models include [[TDS210]] (60 MHz dual-channel) and [[TDS224]] (100 MHz quad-channel). | |||
{{ | {{BeginSpecs}} | ||
{{Spec | Bandwidth | 100 MHz (20 MHz at 2 mV/Div and 5 mV/Div, 20 MHz at 10 mV/Div in Peak Detect mode) }} | |||
{{Spec | Sampling rate | 1 GS/s }} | |||
{{Spec | Sweep | 5 ns/Div to 5 s/Div }} | |||
{{Spec | Record Length | 2,500 sample points per channel }} | |||
{{Spec | Deflection | 2 mV/Div to 5 V/Div, 1-2-5 }} | |||
{{Spec | Resolution | 8 bit (256 levels over 10.24 vertical divisions) }} | |||
{{Spec | Features | | |||
* Automatic Measurements: Period, frequency, cycle RMS, mean, peak-to-peak | |||
* Acquisition Modes: Sample, Average, Peak Detect - High frequency and random glitch capture | |||
* Waveform Storage: Two 2,500 point reference waveforms | |||
* Setups: 5 front panel setups | |||
* Cursors (Voltage, time) - measure Delta T, 1/Delta T, Delta V | |||
* Waveform Processing: Arithmetic Operators Add, subtract | |||
* Single button automatic setup on selected input signal for vertical, horizontal and trigger systems | |||
* Backlit monochrome LCD with adjustable multilevel contrast | |||
* Persistence: Off, 1 sec, 2 sec, 5 sec, infinite | |||
* X-Y mode | |||
}} | |||
{{EndSpecs}} | |||
== | ==Software== | ||
* [[Media:066-0002-00.zip|Waveform Converter For Oscilloscopes 066-0002-00]] (ZIP) | |||
* [[Media:066-0104-00.zip|File Transfer Utility From TDS Scope To PC 066-0104-00]] (ZIP) | |||
* [[Media:066-0106-00.zip|TDS200 series waveform transfer Mac as ASCII - 066-0106-00]] (ZIP) | |||
* [[Media:066-0108-00.zip|TDS200 series 2XX sample RS232 program - 066-0108-00]] (ZIP) | |||
* [[Media:066-0109-00.zip|DOS program to display FFT - 066-0109-00]] (ZIP) | |||
* [[Media:066-0176-00.zip|WFM to ASCII Waveform Converter - UNIX Version For Sun Spark Stations 066-0176-00]] (ZIP) | |||
* [[Media:066-0177-00.zip|Hardcopy from TDS to PC Using HPIP 82335B Interface Card 066-0177-00]] (ZIP) | |||
* [[Media:066-0178-00.zip|Example Program To Get Crossing Levels 066-0178-00]] (ZIP) | |||
* [[Media:066-0179-00.zip|TDS ISF File To CSV File Conversion Utility 066-0179-00]] (ZIP) | |||
* [[Media:066-0188-00.zip|Transfer 2 Byte Data From TDS Oscilloscopes QuickBasic 066-0188-00]] (ZIP) | |||
* [[Media:066-0194-00.zip|TDS Waveform Logging Sample Program 066-0194-00]] (ZIP) | |||
* [[Media:066-0196-00.zip|Load TDS Floppy MathCAD Files Into MathCAD 066-0196-00]] (ZIP) | |||
* [[Media:066-0197-00.zip|Transfer TDS Hardcopy Screens To PC Via GPIB 066-0197-00]] (ZIP) | |||
* [[Media:066-0198-00.zip|Transfer Setups Between TDS Oscilloscopes 066-0198-00]] (ZIP) | |||
* [[Media:066-0200-00.zip|VB Program To Capture TDS Extended Waveforms 066-0200-00]] (ZIP) | |||
* [[Media:066-0934-03.zip|Wavestar for Oscilloscopes V3.0.0 - 066-0934-03]] (ZIP) (105 Mb) | |||
* [[Media:066-0938-09.zip|TekVISA Connectivity Software V4.0.4 - 066-0938-09]] (ZIP) (447 Mb) | |||
* [[Media:066-0938-11.zip|TekVISA Connectivity Software V4.1.1 - 066-0938-11]] (ZIP) (101 Mb) | |||
* [[Media:066-0938-12.zip|TekVISA Connectivity Software V4.2.0 - 066-0938-12]] (ZIP) (101 Mb) | |||
* [[Media:066-0939-14.zip|Openchoice Desktop Application V2.6 - 066-0939-14]] (ZIP) (117 Mb) | |||
* [[Media:066-0939-15.zip|Openchoice Desktop Application V2.8 - 066-0939-15]] (ZIP) (117 Mb) | |||
==Firmware== | |||
* [[Media:TDS210-220_v1.06_Firmware_163-0792-01.zip|TDS210-220 v1.06 Firmware - 163-0792-01]] (ZIP) | |||
* [[Media:TDS210-220_v1.09_Firmware_163-0792-02.zip|TDS210-220 v1.09 Firmware - 163-0792-02]] (ZIP) | |||
* [[Media:163-0792-03.zip|TDS210-220 v1.16 Firmware - 163-0792-03]] (ZIP) | |||
* [[Media:TDS210-220_v1.17_Firmware_163-0792-04.zip|TDS210-220 v1.17 Firmware - 163-0792-04]] (ZIP) | |||
* [[Media:TDS210-220_v1.19_Firmware_163-0792-06.zip|TDS210-220 v1.19 Firmware - 163-0792-06]] (ZIP) | |||
==Options== | |||
* [[TDS2HM]] Hard Copy module: | |||
** Centronics parallel (printer) | |||
* [[TDS2CM]], [[TDS2CMA]], [[TDS2CMAX]] Communications module: | |||
** Centronics parallel (printer), RS-232 serial, GPIB | |||
* [[TDS2MM]] Measurement Extension Module: | |||
** Functions of TDS2CM plus: | |||
** 2048-point FFT, with Hanning, Flat Top, Rectangular windows | |||
** Automatic Measurements - Rise/fall time, positive/negative pulse width | |||
==Optional Accessories== | |||
* RM200 – Rack mount kit | |||
* AC220 – Soft case | |||
* HCTDS32 – Hard case | |||
==Links== | |||
* [https://www.youtube.com/watch?v=9N8UKwn4okM Loose BNC fix and Recall mod] – Near Far Media @ YouTube | |||
* [https://www.youtube.com/watch?v=_KYNugg-0JI Replacing LCD backlight CCFL tube] – Near Far Media @ YouTube | |||
==Pictures== | |||
<gallery> | <gallery> | ||
Tek tds220 1.jpg | Tek tds220 1.jpg | ||
TDS220-interface-module.jpg |Interface module | |||
Tek tds220 3.jpg | |||
Tek tds220 2.jpg | Tek tds220 2.jpg | ||
Tek tds220 | Tek tds220 trace.jpg|TDS 220 | ||
Tek tds 220.jpg | |||
Tek tds220 top.jpg|TDS 220 | |||
Tek tds220 rear.jpg|TDS 220 | |||
TDS210FrontCover.jpg|Front Cover Installed | |||
</gallery> | </gallery> | ||
[[Category:TDS200 series scopes]] | [[Category:TDS200 series scopes]] | ||
Latest revision as of 06:04, 12 July 2023
The Tektronix TDS220 is a portable two-channel digital scope with 1 GS/s sampling rate and 100 MHz bandwidth.
Sister models include TDS210 (60 MHz dual-channel) and TDS224 (100 MHz quad-channel).
Key Specifications
Bandwidth | 100 MHz (20 MHz at 2 mV/Div and 5 mV/Div, 20 MHz at 10 mV/Div in Peak Detect mode) |
---|---|
Sampling rate | 1 GS/s |
Sweep | 5 ns/Div to 5 s/Div |
Record Length | 2,500 sample points per channel |
Deflection | 2 mV/Div to 5 V/Div, 1-2-5 |
Resolution | 8 bit (256 levels over 10.24 vertical divisions) |
Features |
|
Software
- Waveform Converter For Oscilloscopes 066-0002-00 (ZIP)
- File Transfer Utility From TDS Scope To PC 066-0104-00 (ZIP)
- TDS200 series waveform transfer Mac as ASCII - 066-0106-00 (ZIP)
- TDS200 series 2XX sample RS232 program - 066-0108-00 (ZIP)
- DOS program to display FFT - 066-0109-00 (ZIP)
- WFM to ASCII Waveform Converter - UNIX Version For Sun Spark Stations 066-0176-00 (ZIP)
- Hardcopy from TDS to PC Using HPIP 82335B Interface Card 066-0177-00 (ZIP)
- Example Program To Get Crossing Levels 066-0178-00 (ZIP)
- TDS ISF File To CSV File Conversion Utility 066-0179-00 (ZIP)
- Transfer 2 Byte Data From TDS Oscilloscopes QuickBasic 066-0188-00 (ZIP)
- TDS Waveform Logging Sample Program 066-0194-00 (ZIP)
- Load TDS Floppy MathCAD Files Into MathCAD 066-0196-00 (ZIP)
- Transfer TDS Hardcopy Screens To PC Via GPIB 066-0197-00 (ZIP)
- Transfer Setups Between TDS Oscilloscopes 066-0198-00 (ZIP)
- VB Program To Capture TDS Extended Waveforms 066-0200-00 (ZIP)
- Wavestar for Oscilloscopes V3.0.0 - 066-0934-03 (ZIP) (105 Mb)
- TekVISA Connectivity Software V4.0.4 - 066-0938-09 (ZIP) (447 Mb)
- TekVISA Connectivity Software V4.1.1 - 066-0938-11 (ZIP) (101 Mb)
- TekVISA Connectivity Software V4.2.0 - 066-0938-12 (ZIP) (101 Mb)
- Openchoice Desktop Application V2.6 - 066-0939-14 (ZIP) (117 Mb)
- Openchoice Desktop Application V2.8 - 066-0939-15 (ZIP) (117 Mb)
Firmware
- TDS210-220 v1.06 Firmware - 163-0792-01 (ZIP)
- TDS210-220 v1.09 Firmware - 163-0792-02 (ZIP)
- TDS210-220 v1.16 Firmware - 163-0792-03 (ZIP)
- TDS210-220 v1.17 Firmware - 163-0792-04 (ZIP)
- TDS210-220 v1.19 Firmware - 163-0792-06 (ZIP)
Options
- TDS2HM Hard Copy module:
- Centronics parallel (printer)
- TDS2CM, TDS2CMA, TDS2CMAX Communications module:
- Centronics parallel (printer), RS-232 serial, GPIB
- TDS2MM Measurement Extension Module:
- Functions of TDS2CM plus:
- 2048-point FFT, with Hanning, Flat Top, Rectangular windows
- Automatic Measurements - Rise/fall time, positive/negative pulse width
Optional Accessories
- RM200 – Rack mount kit
- AC220 – Soft case
- HCTDS32 – Hard case
Links
- Loose BNC fix and Recall mod – Near Far Media @ YouTube
- Replacing LCD backlight CCFL tube – Near Far Media @ YouTube
Pictures
-
-
Interface module
-
-
-
TDS 220
-
-
TDS 220
-
TDS 220
-
Front Cover Installed