The '''Tektronix 013-0055-00 Plug-In Extension''' is used for calibrating and repairing | |||
Tektronix [[500-series scopes|530, 540, 550]], and [[585|580]] series oscilloscopes as well as their plug-ins. | |||
The 013-0055-00 extender is optimized for [[580-series scopes]], which has the plug-in pin-out flipped 180° over earlier 5xx series. | |||
Pins 8,9,11,14,16 are connected via 93 Ω coax; these pins are signal and trigger lines on the 580 series, | |||
but are mostly power pins on the earlier series. | |||
* [[Media:061-888.pdf|013-055 Datasheet (April 1963, OCR)]] | |||
* [[Media:061-0888-00.pdf|013-0055-00 Datasheet (August 1965 Revision, OCR)]] | |||
<gallery> | <gallery> | ||
013_0055_0.jpg | |||
013_0055_1.jpg | |||
013_0055_2.jpg | |||
</gallery> | </gallery> | ||
[[Category:Calibration fixtures]] |
Latest revision as of 15:57, 9 March 2024
The Tektronix 013-0055-00 Plug-In Extension is used for calibrating and repairing Tektronix 530, 540, 550, and 580 series oscilloscopes as well as their plug-ins.
The 013-0055-00 extender is optimized for 580-series scopes, which has the plug-in pin-out flipped 180° over earlier 5xx series.
Pins 8,9,11,14,16 are connected via 93 Ω coax; these pins are signal and trigger lines on the 580 series, but are mostly power pins on the earlier series.