067-0587-01: Difference between revisions
No edit summary |
No edit summary |
||
Line 41: | Line 41: | ||
File:067-0587-01 2.jpg | File:067-0587-01 2.jpg | ||
Tek 067-0587-00.jpg|067-0587-00 | Tek 067-0587-00.jpg|067-0587-00 | ||
Tek 067-0587-01 trace.jpg | |||
</gallery> | </gallery> | ||
[[Category:7000 series special-function plugins]] | [[Category:7000 series special-function plugins]] | ||
[[Category:Calibration fixtures]] | [[Category:Calibration fixtures]] |
Revision as of 01:19, 29 October 2016
Template:Plugin Sidebar 2 The Tektronix 067-0587-01 Calibration Fixture is designed to standardize the horizontal and vertical deflection factors of 7000 series mainframes. It provides a uniform step calibrated deflection factor, a fast risetime step response function and a common-mode input test for both the vertical and trigger systems. It is the predecessor of the 067-0587-02.
Key Specifications
Risetime | 300 ps |
---|---|
Bandwidth | 500 MHz (067-0587-01) / 250 MHz (067-0587-00) |
Internals
It uses one custom Tektronix IC, the 155-0078-00. The manual says it is a high frequency push-pull amplifier.
It uses one tunnel diode, the 152-0177-00, a 10 mA, 4 pF diode in a DO-17 package. It also uses 12 Tektronix custom Schottky diodes, part 152-0442-00 (speced as matched pairs) in the tunnel diode pulse shaper and in the CW peak-to-peak detector. The service manual calls them "disconnect diodes", physically they look like snap-off diodes found in other Tektronix fast risetime pulsers. Note that there is a typo in the service manual for CR80, CR84, and CR85 in the peak-to-peak detector.
Links
- Tek 067-0587-01 @ analogdesign.be - photos and description
- 067-0587-02 page @ amplifier.cd (comparing -01 and -02, lots of pictures, text in German)
Pictures
-
-
-
067-0587-00
-