The Tektronix S-53 Trigger Recognizer is essentially the entire trigger circuit of an oscilloscope. It | The Tektronix S-53 Trigger Recognizer is essentially the entire trigger circuit of an oscilloscope. It | ||
is rated to 1GHz and has a BNC input with 50-ohm impedance. It uses tunnel diode triggering with an | is rated to 1GHz and has a BNC input with 50-ohm impedance. It uses tunnel diode triggering with an | ||
amplifier before the tunnel diode. | amplifier before the tunnel diode. The input signal to trigger out jitter is rated at 15ps or less. | ||
The trigger-out signal is 1V into 50 ohms, with 600mV/ns slew rate. | |||
* [http://w140.com/tek_s53.pdf Tektronix S-53 Manual (bad) (PDF)] | * [http://w140.com/tek_s53.pdf Tektronix S-53 Manual (bad) (PDF)] |
Revision as of 14:55, 28 April 2011
The Tektronix S-53 Trigger Recognizer is essentially the entire trigger circuit of an oscilloscope. It is rated to 1GHz and has a BNC input with 50-ohm impedance. It uses tunnel diode triggering with an amplifier before the tunnel diode. The input signal to trigger out jitter is rated at 15ps or less. The trigger-out signal is 1V into 50 ohms, with 600mV/ns slew rate.