Revision as of 23:11, 22 March 2021
The Tektronix 468 is a digital/analog scope, essentially a 465B with an added 25 MS/s 8 bit digitizer.
Specifications
- Digital mode: Sampling rate 25 MS/s, bandwidth 10 MHz (sine)/2.5 MHz (pulse), resolution 8 bit
- Analog mode: 100 MHz bandwidth
- GPIB option
- please add more ...
Repair issues
Many 468s used Mostek MKB36000 masked ROMs that can suffer from "ROM rot". It may be necessary to replace the 160-0459-01 and 160-0759-01 ROMs with 2764 EPROMs through a 2364/2764 adapter. Another option might be using the MCM68766 EPROM.
-
replaced ROM by 2764 with homemade 2364/2764 adapter
-
Result of bad ROM by verification-check.
ROM images
A16 STORAGE-DISPLAY Circuit Board Replacement ERROR in SERVICE Manual Schematic and Parts list (See Repairs)
Links
Pictures
-
-
-
front
-
top
-
Top Digital
-
right
-
left
-
bottom
-
rear
-
Storage Boards