TDS744A: Difference between revisions

From TekWiki
Jump to navigation Jump to search
(Added manuals.)
(Added Option 05 install manual and picture.)
Line 12: Line 12:
* [[Media:061-4094-02.pdf|TDS, TLS & CTS FDD Replacement 061-4094-02]]
* [[Media:061-4094-02.pdf|TDS, TLS & CTS FDD Replacement 061-4094-02]]
* [[Media:070-8709-07.pdf|TDS400A/500A/600A/700A Programmer 070-8709-07]]
* [[Media:070-8709-07.pdf|TDS400A/500A/600A/700A Programmer 070-8709-07]]
* [[Media:070-8748-02.pdf|TDS Family Opt 05 Video Trigger Interface 070-8709-07]]
* [[Media:070-8748-02.pdf|TDS Family Opt 05 Video Trigger Interface 070-8709-02]]
* [[Media:070-9636-02.pdf|TDS Family Opt 05 Video Trigger Interface Install 070-9636-02]]
* [[Media:070-8990-04.pdf|TDS684A/744A/784A Performance Verification and Specifications 070-8990-04]]
* [[Media:070-8990-04.pdf|TDS684A/744A/784A Performance Verification and Specifications 070-8990-04]]
* [[Media:070-8991-02.pdf|TDS684A/744A/784A User 070-8991-02]] / <small>[[Media:070-8991-02 c2.pdf|Alternate copy]]</small>
* [[Media:070-8991-02.pdf|TDS684A/744A/784A User 070-8991-02]] / <small>[[Media:070-8991-02 c2.pdf|Alternate copy]]</small>
Line 78: Line 79:
==Pictures==
==Pictures==
<gallery>
<gallery>
Tek_TDS744A_Front.jpeg | Front
Tek_TDS744A_Front.jpeg|Front
Tek_TDS744A_Back.jpeg | Rear
Tek_TDS744A_Back.jpeg|Rear
</gallery>
</gallery>


===Internals===
===Internals===
<gallery>
<gallery>
Tek_TDS744A_Top.jpeg | Top - Processor/Display Board
Tek_TDS744A_Top.jpeg|Top - Processor/Display Board
Tek_TDS744A_Bottom.jpeg |Bottom - Acquisition board
Tek_TDS744A_Bottom.jpeg|Bottom - Acquisition board
Tek_TDS744A_PS_CRT_1.jpeg | Power supply & CRT board
Tek_TDS744A_PS_CRT_1.jpeg|Power supply & CRT board
Tek_TDS744A_PS_CRT_2.jpeg | Power supply & CRT board
Tek_TDS744A_PS_CRT_2.jpeg|Power supply & CRT board
Tek_TDS744A_LHS.jpeg | LHS
Tek_TDS744A_LHS.jpeg|Left Side
Tek_TDS744A_RHS.jpeg | RHS
Tek_TDS744A_RHS.jpeg|Right Side
TDS5-6-700_Option_05_TV_Trigger_Internal_Parts.jpg|Option 05 Internal Parts
</gallery>
</gallery>




[[Category:TDS700 series scopes]]
[[Category:TDS700 series scopes]]

Revision as of 03:40, 12 November 2021

Manuals – Specifications – Links – Pictures

The TDS744 is a 500 MHz, 2 GS/s four-channel digital scope with a color screen.

Key Specifications

Bandwidth 500 MHz at 10 mv/div and above; 500 MHz @ 5 mV/div; 500 MHz @ 2 mV/div; 450 MHz @ 1 mV/div
Sample rate 1 channel @ 2 GS/s, 2 channels @ 1 GS/s, 3 or 4 channels @ 500 MS/s
Resolution 8 bit
Record length 50k samples per channel (500k with option 1M)
Acquisition modes sample, envelope, average, high-resolution, peak-detect
Display Color; Zoom
Trigger modes Edge, logic, pulse; Video trigger with option 05 (NTSC, SECAM, PAL, HDTV, and FlexFormat)
Storage 1.44 Mbyte, 3.5 inch, DOS 3.3-or-later floppy disk. NVRAM storage for saving waveforms, hardcopies, and setups. Units with option HD present (requires additional hardware) have a hard disk drive
I/O Full GPIB programmability
Hardcopy Using GPIB, RS-232, or Centronics ports

Software

Firmware

Options

  • 05 - Video Trigger - Oscilloscope comes with tools that allow investigation of a range of NTSC, PAL, SECAM, and high definition TV signals.
  • 1M - 4M acquisition length - Extends standard acquisition length from 50,000 points per channel to 130,000 samples on three or four channels, 250,000 samples on two channels, and 500,000 samples on one channel.
  • 13 - RS-232C and Centronics hardcopy interfaces - Add RS-232-C and Centronics interface ports.
  • 1F - Floppy disk drive - Add 3.5 inch, 1.44 MByte floppy disc drive.
  • 2F - Advanced DSP math - Add advanced DSP math features such as FFT, integration, and differentiation.
  • 2C - Communication Signal Analyzer - Oscilloscope comes configured for communications signal triggering and mask testing.
  • 3C - P6701B with system calibration - Oscilloscope comes with a P6701B and calibrated short-wavelength optical reference receiver on channel 1.
  • 4C - P6703B with system calibration - Oscilloscope comes with a P6703B and calibrated long-wavelength optical reference receiver on channel 1.
  • 2M - 8M acquisition length - TDS 520D, 724D: To 2M samples on two channels and 4M on one channel. TDS 540D, 580D, 714L, 754D, 784D, 794D: To 2M samples on three or four channels, 4M on two channels, and 8M samples on one channel (Option includes a hard disk and is only available for the models listed above.)

Links

Pictures

Internals