Line 12: | Line 12: | ||
and that is what Tektronix did. | and that is what Tektronix did. | ||
The 454 weighs 29 pounds and consumes about 130 watts. | The 454 weighs 29 pounds and consumes about 130 watts. | ||
The 454 is the fastest general-purpose Tektronix scope | The 454 is the fastest general-purpose Tektronix scope | ||
that does not use proprietary hybrid circuits | that does not use proprietary hybrid circuits | ||
Line 17: | Line 18: | ||
(The [[519]] is much faster, but its sensitivity is 10V/div | (The [[519]] is much faster, but its sensitivity is 10V/div | ||
so it isn't really a general-purpose scope.) | so it isn't really a general-purpose scope.) | ||
With the input sensitivity set to 10mV/div and above, | |||
the 454A has a vertical bandwidth of 150MHz. | |||
At 5mV/div it is 100MHz, and at 2mV/div it is 50MHz. | |||
It is possible to cascade the channel-1 and channel-2 | |||
input amplifiers to obtain a sensitivity of 400uV/div. | |||
In that configuration, the vertical bandwidth is 33MHz. | |||
The 454 was [[introduced in 1967|introduced in March 1967]]. | The 454 was [[introduced in 1967|introduced in March 1967]]. | ||
The 454A was [[introduced in 1971]]. | The 454A was [[introduced in 1971]]. |
Revision as of 16:48, 10 February 2013
The Tektronix 454 can be seen as an improved 453. The bandwidth is 150MHz, compared to 50MHz for a 453. The 454 uses a CRT with distributed vertical deflection plates. Without distributed deflection plates, a CRT designer is forced to trade off deflection sensitivity for deflection speed. A CRT with low sensitivity requires a vertical amplifier with a large output swing. It is difficult to find transistors that have both large voltage swing and high speed. Most transistors with high Ft values also have quite low collector breakdown voltages. So the most practical solution was to use distributed deflection plates, and that is what Tektronix did. The 454 weighs 29 pounds and consumes about 130 watts.
The 454 is the fastest general-purpose Tektronix scope that does not use proprietary hybrid circuits or proprietary integrated circuits. (The 519 is much faster, but its sensitivity is 10V/div so it isn't really a general-purpose scope.) With the input sensitivity set to 10mV/div and above, the 454A has a vertical bandwidth of 150MHz. At 5mV/div it is 100MHz, and at 2mV/div it is 50MHz. It is possible to cascade the channel-1 and channel-2 input amplifiers to obtain a sensitivity of 400uV/div. In that configuration, the vertical bandwidth is 33MHz.
The 454 was introduced in March 1967. The 454A was introduced in 1971.
-
454A Front
-
454A Bottom
-
454A Vertical amp
-
454A Top
-
-