TDS680: Difference between revisions
Jump to navigation
Jump to search
Jaredcabot (talk | contribs) (Added PCMCIA HD option photo) |
Jaredcabot (talk | contribs) (Added specs and firmware) |
||
Line 38: | Line 38: | ||
* [[Media:070-9874-02.pdf|TDS600B Performance Verification and Specifications 070-9874-02]] | * [[Media:070-9874-02.pdf|TDS600B Performance Verification and Specifications 070-9874-02]] | ||
* [[Media:070-9876-00.pdf|TDS680B Programmer Manual 070-9876-00]] | * [[Media:070-9876-00.pdf|TDS680B Programmer Manual 070-9876-00]] | ||
* [[Media:071-0130-03.pdf|TDS600B User 071-0130-03]] | * [[Media:071-0130-03.pdf|TDS600B User Manual 071-0130-03]] | ||
* [[Media:071-0135-00.pdf|TDS600B Performance Verification and Specifications 071-0135-00]] | * [[Media:071-0135-00.pdf|TDS600B Performance Verification and Specifications 071-0135-00]] | ||
* [[Media:071-0136-00.pdf|TDS600B Service Manual 071-0136-00]] | * [[Media:071-0136-00.pdf|TDS600B Service Manual 071-0136-00]] | ||
Line 49: | Line 49: | ||
}} | }} | ||
The '''Tektronix TDS680''' is a 1 GHz, 5 GS/s digital storage scope. | The '''Tektronix TDS680''' is a 1 GHz, 5 GS/s 2-channel digital storage scope with a monochrome screen.<br> | ||
Two plus Two channel operation allows up to two of the four channels to be displayed simultaneously.<br> | |||
Channels not displayed can be used to couple a triggering signal to the oscilloscope. | |||
{{ | {{BeginSpecs}} | ||
{{Spec | Bandwidth | 1 GHz at 10 mv/div and above; 750 MHz @ 5 mV/div; 600 MHz @ 2 mV/div; 500 MHz @ 1 mV/div }} | |||
{{Spec | Sample rate | 1 or 2 channels @ 5 GS/s }} | |||
{{Spec | Number of Channels | 2 + 2 }} | |||
{{Spec | Vertical Sensitivity| 1 mV to 10 V/div with calibrated fine adjustment }} | |||
{{Spec | Resolution | 8 bit }} | |||
{{Spec | Time Base Range| 200 ps to 10 s/div }} | |||
{{Spec | Record length | 15k samples per channel }} | |||
{{Spec | Acquisition modes | sample, envelope, average, high-resolution, peak-detect }} | |||
{{Spec | Display | Monochrome }} | |||
{{Spec | Trigger modes | Edge, logic, pulse; Video trigger with option 05 ([[NTSC]], [[SECAM]], [[PAL]], HDTV, and FlexFormat) }} | |||
{{Spec | Storage | 1.44 Mbyte, 3.5 inch, DOS 3.3-or-later floppy disk. NVRAM storage for saving waveforms, hardcopies, and setups. Units with option HD present (requires additional hardware) have a hard disk drive }} | |||
{{Spec | I/O | Full GPIB programmability }} | |||
{{Spec | Hardcopy | Using [[GPIB]], [[RS-232]], or Centronics ports }} | |||
{{EndSpecs}} | |||
==Software== | ==Software== | ||
Line 61: | Line 77: | ||
* [[Media:066-0125-00.zip|Enhanced Printing Utility for TDS Family 066-0125-00]] (ZIP) | * [[Media:066-0125-00.zip|Enhanced Printing Utility for TDS Family 066-0125-00]] (ZIP) | ||
* [[Media:Tdsrteup_(TDS_runtime_Environment_TDSRTE1).zip|TDS runtime Environment TDSRTE1 066-0127-00]] (ZIP) | * [[Media:Tdsrteup_(TDS_runtime_Environment_TDSRTE1).zip|TDS runtime Environment TDSRTE1 066-0127-00]] (ZIP) | ||
==Firmware== | |||
* [[Media:TDS680B_v4.2e_Firmware.zip|TDS680B v4.2e Firmware]] (ZIP) | |||
* [[Media:TDS680B_v4.4.1e_Firmware.zip|TDS680B v4.4.1e Firmware]] (ZIP) | |||
==Pictures== | ==Pictures== |
Revision as of 01:38, 1 May 2022
The Tektronix TDS680 is a 1 GHz, 5 GS/s 2-channel digital storage scope with a monochrome screen.
Two plus Two channel operation allows up to two of the four channels to be displayed simultaneously.
Channels not displayed can be used to couple a triggering signal to the oscilloscope.
Key Specifications
Bandwidth | 1 GHz at 10 mv/div and above; 750 MHz @ 5 mV/div; 600 MHz @ 2 mV/div; 500 MHz @ 1 mV/div |
---|---|
Sample rate | 1 or 2 channels @ 5 GS/s |
Number of Channels | 2 + 2 |
Vertical Sensitivity | 1 mV to 10 V/div with calibrated fine adjustment |
Resolution | 8 bit |
Time Base Range | 200 ps to 10 s/div |
Record length | 15k samples per channel |
Acquisition modes | sample, envelope, average, high-resolution, peak-detect |
Display | Monochrome |
Trigger modes | Edge, logic, pulse; Video trigger with option 05 (NTSC, SECAM, PAL, HDTV, and FlexFormat) |
Storage | 1.44 Mbyte, 3.5 inch, DOS 3.3-or-later floppy disk. NVRAM storage for saving waveforms, hardcopies, and setups. Units with option HD present (requires additional hardware) have a hard disk drive |
I/O | Full GPIB programmability |
Hardcopy | Using GPIB, RS-232, or Centronics ports |
Software
- TDS600B Field Adjustment Software 063-1908-01 (ZIP)
- TDS600C v1.73 Field Adjustment Software.zip (ZIP)
- Tektronix TDS300, 400, 500, 600, 700, 800 AWE Drivers 066-0087-00 (ZIP)
- Tektronix Wavestar 2012.05.09.11.07.29 16456 EN (ZIP, 102MB) Product Key: WSTRO618650124
- Enhanced Printing Utility for TDS Family 066-0125-00 (ZIP)
- TDS runtime Environment TDSRTE1 066-0127-00 (ZIP)
Firmware
- TDS680B v4.2e Firmware (ZIP)
- TDS680B v4.4.1e Firmware (ZIP)
Pictures
-
TDS680B Front
-
TDS680C Front
-
S-52 Single Shot
-
Option 05 Internal Parts
-
Option HD Internal Parts, 2.5" Disk Version
-
Option HD Internal Parts, PCMCIA Disk Version