TDS714L: Difference between revisions
Jump to navigation
Jump to search
Jaredcabot (talk | contribs) (Added software) |
Jaredcabot (talk | contribs) (Added manuals) |
||
Line 13: | Line 13: | ||
* [[Media:061-4094-02.pdf|TDS, TLS & CTS FDD Replacement Instructions 061-4094-02]] | * [[Media:061-4094-02.pdf|TDS, TLS & CTS FDD Replacement Instructions 061-4094-02]] | ||
* [[Media:070-8432-04.pdf|TLS Logic Scope and TDS Series Oscilloscopes Rackmount Installation 070-8432-04]] | * [[Media:070-8432-04.pdf|TLS Logic Scope and TDS Series Oscilloscopes Rackmount Installation 070-8432-04]] | ||
* [[Media:070-8567-01.pdf|Option 13 RS-232/Centronics Hardcopy Interface Instruction Manual 070-8567-01]] | |||
* [[Media:070-8582-01.pdf|Option 2F Advanced DSP Math Instruction Manual 070-8582-01]] | |||
* [[Media:070-8748-02.pdf|TDS Family Opt 05 Video Trigger Interface Instruction Manual 070-8709-02]] | * [[Media:070-8748-02.pdf|TDS Family Opt 05 Video Trigger Interface Instruction Manual 070-8709-02]] | ||
* [[Media:070-8919-00.pdf|TTiP TDS Telecommunication Templates & i-Pattern Software 070-8919-00]] | * [[Media:070-8919-00.pdf|TTiP TDS Telecommunication Templates & i-Pattern Software 070-8919-00]] |
Revision as of 22:15, 1 March 2023
The Tektronix TDS714L is a 4 channel 500 MHz, 500 MS/s digital storage scope with a color screen.
The TDS714L is compatible with the Iomega Zip and Zip Plus Drive.
Key Specifications
Bandwidth | 500 MHz |
---|---|
Sample rate | 1 or 2 channels @ 500 MS/s |
Number of Channels | 4 |
Vertical Sensitivity | 1 mV to 10 V/div with calibrated fine adjustment |
Resolution | 8 bit |
Time Base Range | 500 ps to 10 s/div |
Record length | 250K samples on 1 or two channels, 130K on 3 or 4 channels |
Record Length (2M Option only) | 8 M points on 1 channel; 4 M points on 2 channels ; 2 M points on 3 or 4 channels |
Acquisition modes | sample, envelope, average, high-resolution, peak-detect |
Display | Color; Zoom |
Trigger modes | Edge, logic, pulse; Video trigger with option 05 (NTSC, SECAM, PAL, HDTV, and FlexFormat) |
Storage | 1.44 Mbyte, 3.5 inch, DOS 3.3-or-later floppy disk. NVRAM storage for saving waveforms, hardcopies, and setups. Units with option HD present (requires additional hardware) have a hard disk drive |
I/O | Full GPIB programmability |
Hardcopy | Using GPIB, RS-232, or Centronics ports, also compatible with Zip 100/250 disk drives |
Software
- TDS Family Programming Examples Software 063-1134-00 V1.2 (ZIP)
- Waveform Converter For Oscilloscopes 066-0002-00 (ZIP)
- AWE Drivers For Tektronix Oscilloscopes 066-0087-00 (ZIP)
- File Transfer Utility From TDS Scope To PC 066-0104-00 (ZIP)
- Telecom Test and I-Pattern Software TTiP 066-0119-00 (ZIP)
- Enhanced Printing Utility for TDS Family 066-0125-00 (ZIP)
- TDS runtime Environment TDSRTE1 066-0127-00 (ZIP)
- Tektronix TDS500C/700C Custom Masks 066-0165-00 (ZIP)
- WFM to ASCII Waveform Converter - UNIX Version For Sun Spark Stations 066-0176-00 (ZIP)
- Hardcopy from TDS to PC Using HPIP 82335B Interface Card 066-0177-00 (ZIP)
- Example Program To Get Crossing Levels 066-0178-00 (ZIP)
- TDS ISF File To CSV File Conversion Utility 066-0179-00 (ZIP)
- TDS Sandisk Hard Disk Patch Utility 066-0183-00 (ZIP)
- Transfer 2 Byte Data From TDS Oscilloscopes QuickBasic 066-0188-00 (ZIP)
- TDS Waveform Logging Sample Program 066-0194-00 (ZIP)
- Load TDS Floppy MathCAD Files Into MathCAD 066-0196-00 (ZIP)
- Transfer TDS Hardcopy Screens To PC Via GPIB 066-0197-00 (ZIP)
- Transfer Setups Between TDS Oscilloscopes 066-0198-00 (ZIP)
- VB Program To Capture TDS Extended Waveforms 066-0200-00 (ZIP)
- TDS Series WFM File Formatter 066-0489-00 (ZIP)
- Tektronix Wavestar 2012.05.09.11.07.29 16456 EN 066-0934-03 (ZIP, 102MB) Product Key: WSTRO618650124
Firmware
- TDS714L v7.1.1e Firmware (ZIP)
- TDS714L v7.2e Firmware (ZIP)
- TDS714L v7.4e Firmware (ZIP)
Options
- 05 - Video Trigger - Oscilloscope comes with tools that allow investigation of a range of NTSC, PAL, SECAM, and high definition TV signals.
- 13 - RS-232C and Centronics hardcopy interfaces - Add RS-232-C and Centronics interface ports.
- 1F - Floppy disk drive - Add 3.5 inch, 1.44 MByte floppy disc drive.
- 2M - 8M acquisition length - To 2M samples on three or four channels, 4M on two channels, and 8M samples on one channel.
- HD - Hard Disk - 170Mb internal hard disk drive.
Optional Accessories
- 1K - Add K420 scope cart
- 1R - Rackmount kit
- 34 - P6247 differential probe
- 35 - P6243 active probe
- 36 - P6139A passive probe
- C3 - Three years calibration
- D1 - Calibration data report
- D3 - Calibration data for C3
Standard Accessories
- 071-0130-XX - User Manual with Programmers Manual Help Disk
- 071-0628-XX - TDS714L Supplement
- 020-2313-XX - Reference
- 071-0630-XX - Technical Reference: Performance Verification and Specifications
- P6139A - Probes: Four P6139A 10X, 500 MHz Passive probes
- 200-3696-01 - Front Cover
- 016-1268-00 - Accessory Pouch (only without Option 1R)
- 161-0230-01 - U.S. Power Cord
Optional Accessories
- 071-0627-XX - Service Manual
- K420 - Oscilloscope Cart
- 016-1236-00 - Rack Mount Kit (for field conversion)
- 016-1268-00 - Accessory Pouch
- 016-0909-01 - Soft-Sided Carrying Case
- 016-1135-00 - Transit Case
- 012-0991-01 - GPIB Cable (1 meter)
- 012-0991-00 - GPIB Cable (2 meter)
- 012-1214-00 - Centronics Cable
- 012-1298-00 - RS-232 Cable
Links
See the Repairs page regarding HDD/FDD replacements.
- Tek Forum threads:
- EEVBlog Forum Threads:
- Youtube
- Simmconn Labs LCD replacement kits for CRT-based TDS O-scopes
- Wavestar Product Key
- TDS error log viewer
- Enabling options via GPIB interface - ko4bb.com
Pictures
-
TDS714L Front
-
TDS714L Rear
-
TDS714L 3/4 View
-
TDS714L
-
TDS714L
-
TDS714L
-
Option 05 Internal Parts
-
Option HD Internal Parts, 2.5" Disk Version
-
Option HD Internal Parts, PCMCIA Disk Version