Line 16: Line 16:
The single and delta markers provide direct readout of frequency and amplitude information of any point along any displayed trace.  Or, get the relative (delta) frequency and amplitude information between any two points along any displayed trace or between traces.
The single and delta markers provide direct readout of frequency and amplitude information of any point along any displayed trace.  Or, get the relative (delta) frequency and amplitude information between any two points along any displayed trace or between traces.


The 2714 Cable TV Spectrum Analyzer has features to support the measurements necessary to maintain a function CATV system like: Automatic positioning of visual aural carriers, Visual and aural carrier levels and frequencies for selected channels, Survey of system visual and aural carrier levels and frequencies, Depth of modulation, Aural carrier deviation measurement, Visual carrier-to-noise measurement, and Visual to carrier amplitude and frequency difference measurements.
The 2714 Cable TV Spectrum Analyzer has features to support the measurements necessary to maintain a functional CATV system like: Automatic positioning of visual aural carriers, Visual and aural carrier levels and frequencies for selected channels, Survey of system visual and aural carrier levels and frequencies, Depth of modulation, Aural carrier deviation measurement, Visual carrier-to-noise measurement, and Visual to carrier amplitude and frequency difference measurements.


Additional features include Digital Storage Display (selectable acquisition modes of positive peak only, positive/negative peak, Max hold, Waterfall, and an analog sweep when digital storage is off), Ensemble Averaging, Internal Preamp, Internal Calibrator (accessed through Input Menu), Alternate Reference Level Units (dBm, dBmV, dBV, dBµV, dBµW, and dBµV/m), User-Definable Power-on Status, Center Measure, Graticule Illumination (for CRT photography), and Direct Plot/Print (Printers via Opt. 03 GPIB, or RS-232-C interface via Opt. 08).
Additional features include Digital Storage Display (selectable acquisition modes of positive peak only, positive/negative peak, Max hold, Waterfall, and an analog sweep when digital storage is off), Ensemble Averaging, Internal Preamp, Internal Calibrator (accessed through Input Menu), Alternate Reference Level Units (dBm, dBmV, dBV, dBµV, dBµW, and dBµV/m), User-Definable Power-on Status, Center Measure, Graticule Illumination (for CRT photography), and Direct Plot/Print (Printers via Opt. 03 GPIB, or RS-232-C interface via Opt. 08).