1.8 GHz Spectrum Analyzer
Tektronix 2714

Produced from 1993 to 2000

Manuals
Manuals – Specifications – Links – Pictures

The Tektronix 2714 is a CATV spectrum analyzer with a frequency range of 9 kHz to 1.8 GHz.

The 2714 Cable TV Spectrum Analyzer supports CATV-specific functions like automatic positioning of visual aural carriers, visual and aural carrier levels and frequencies for selected channels, survey of system visual and aural carrier levels and frequencies, depth of modulation, aural carrier deviation measurement, visual carrier-to-noise measurement, and visual to carrier amplitude and frequency difference measurements.

Key Specifications

Frequency 9 kHz to 1.8 GHz; Preamp limited to 600 MHz
Frequency Span 1 kHz/div to 100 MHz/div in 1, 2, 5 sequence (plus 0 Hz and MAX: 180 MHz/div)
Resolution Bandwidth –6 dB bandwidth selections are 300 Hz, 1 kHz, 3 kHz, 10 kHz, 30 kHz, 100 kHz, 300 kHz, 1 MHz and 5 MHz
RF Input impedance 75 Ω
Maximum Safe Input Power +70 dBmV (0.1 W or 2.2 V) continuous peak, ≤100 V DC blocking capacitor
RF Attenuator 0 dB to 50 dB, 2 dB steps
Sensitivity (at 300 Hz RBW) -78 dBmV (-127 dBm); -90 dBmV (-139 dBm) with preamp on
Reference Level -70 dBm to +20 dBm; -23 dBmV to +66.9 dBmV
Sweep Speed 2 sec/Div to 1 µs/Div in 1, 2, 5 sequence
Triggering Modes Free Run, Internal, External, Line, TV Line, and TV Field
Displayed Average Noise −66 dBm to −100 dBm
Display Dynamic Range 80 dB
Dynamic Range ≥100 dBm
Internal Calibrator 100 MHz marker at +18.8 dBmV (-30 dBm)
Power 90 − 132 VAC, 48 to 440 Hz; 90 – 250 VAC, 48 to 63 Hz. At 115 VAC, 60 Hz, 90 W (standard), 105 W max (with options)
Features
  • 124 kB NVRAM to save up to 108 waveform displays, 36 front panel setups, -defined key programs, and antenna factor tables.
  • Single and delta markers – readout of frequency and amplitude
  • Digital storage display
  • Acquisition modes: positive peak only, positive/negative peak, Max hold, Waterfall, an analog sweep (when digital storage is off)
  • Ensemble averaging
  • Internal preamp
  • Internal Calibrator
  • Alternate reference level units (dBm, dBmV, dBV, dBµV, dBµW, and dBµV/m)
  • Direct plot/print (Printers via Opt. 03 GPIB, or RS-232-C interface via Opt. 08).

Options

  • Opt. 03: GPIB Interface (cannot be combined with Opt. 08)
  • Opt. 05: 100 kHz to 1.8 GHz External Tracking Generator (includes option 15)
  • Opt. 07: Add 2704 Inverter/2705 Battery Pack
  • Opt. 08: RS-232 Port (cannot be combined with Opt. 03)
  • Opt. 15: Tek 1405 TV Sideband Adapter interface installed at J101 as SMA female
  • Opt. 30: Rackmount
  • Opt. 33: Travel Line Package (includes Rain cover, Accessory pouch, Gray filter and Carrying strap)
  • Opt. 34: Portable to Rackmount Adapter

Connectors

Front panel: RF INPUT BNC connector (75 Ω, +20 dBm max, 100 V DC blocking capacitor; OPTION (Unknown connector – Service manual only indicates that the front panel position is for a Future Option. No internal tracking generators were available like with the other 2710, 2711, and 2712).

Rear panel: J101 SMA connector (for Opt. 15); J102 EXT TRIG BNC connector (10 kΩ, 50 V (DC + peak AC)); J103 DE-9 female Accessory: Pin 1 Video Input, Pin 2 Ground, Pin 3 Video Output, Pin 6 Sweep Gate, Pin 7 Sweep Output, all others unused); J104 Opt. 03: GPIB connector or Opt. 08: RS-232 interface (Digital Communication Port)