067-0502-00: Difference between revisions

From TekWiki
Jump to navigation Jump to search
No edit summary
No edit summary
Line 13: Line 13:
I have made my own notes for the project of working on the two. Using the schematics for organization, I arrived @ the following table.  I am using a re-organization of the sheets, the block diagram of the –00 and this table:
I have made my own notes for the project of working on the two. Using the schematics for organization, I arrived @ the following table.  I am using a re-organization of the sheets, the block diagram of the –00 and this table:
</blockquote>
</blockquote>
{|
{| class="wikitable"
|Section|-00|-01|Sheet in -00|Sheet in -01|Sheet in proposed consolidated drawing set
|-
| Section
| -00
| -01
| Sheet in -00
| Sheet in -01
| Sheet in proposed consolidated drawing set
|-
| Square Wave calibrator
| Used in both
| Used in both
| 1
| 1
| [s/b 1]
|-
| X100 Amplifier
| Used in -00
| Used in -01
| 2
| --
| [s/b 2]
|-
| Power Supply
| -00 has more sections
| Than –01
| 3
| 2
| [s/b 3A for -00 & 3B for -01]
|-
| T310
| P/N 120-0442-00
| P/N 120-0615-00
| 3
| 2
| 3A/3B
|-
| High voltage, B+
| 285 VRMS, 35  mA 300 VDC, 225 VDC & 100 VDC
| 285 VRMS, 35  mA 300 VDC, 225 VDC & 100 VDC
| 3
| 2
| 3A/3B
|-
| 6.3 VAC (Chopper)
| Used in -00
| Used in -01, noted as 1.84A
| 3
| 2
| 3A/3B
|-
| 100 VRMS (-100 VDC)
| Used in -00, 40 mA
| Used in -01, 31 mA
| 3
| 2
| 3A/3B
|-
| 6.3 VAC (MV 6DJ8)
| Used in -00
| Used in -01
| 3
| 2
| 3A/3B
|-
| 330 VRMS (Floating Supply)
| Used in -00
| Used in -01
| 3
| 2
| 3A/3B
|-
| 20 VRMS (X100 Filaments)
| Used in -00
| Not used in –01 T310
| 3
| 2
| 3A/3B
|-
| Floating power supply
| Used in both; drives Square Wave MV
| Used in both; drives Square Wave MV
| 4
| 3
| [s/b 4]
|}
|}



Revision as of 02:52, 13 September 2014

The Tektronix 067-0502-00 is an instrument designed for calibrating oscilloscope calibrators. It is very similar to the 067-0502-01. What are the differences?

Sherman Foy contributed the following information:

TekWiki asks the question: what is the difference? I have both units and have done an extensive review.

Looking @ the front panels [TNX 4 pix] of the –00 & the –01, it seems that the –01 dropped the X100 Amplifier section. The front panel is re-laid out, but what remains seems to be identical to the corresponding sections from the –00. IOW, the –00 is a superset and the –01 is a subset of the -00.

Note that the –00 transformer [T310] has 6 windings and the –01 transformer [also T310] has 5 windings. Some currents are different, as indicated.

I have made my own notes for the project of working on the two. Using the schematics for organization, I arrived @ the following table. I am using a re-organization of the sheets, the block diagram of the –00 and this table:

Section -00 -01 Sheet in -00 Sheet in -01 Sheet in proposed consolidated drawing set
Square Wave calibrator Used in both Used in both 1 1 [s/b 1]
X100 Amplifier Used in -00 Used in -01 2 -- [s/b 2]
Power Supply -00 has more sections Than –01 3 2 [s/b 3A for -00 & 3B for -01]
T310 P/N 120-0442-00 P/N 120-0615-00 3 2 3A/3B
High voltage, B+ 285 VRMS, 35 mA 300 VDC, 225 VDC & 100 VDC 285 VRMS, 35 mA 300 VDC, 225 VDC & 100 VDC 3 2 3A/3B
6.3 VAC (Chopper) Used in -00 Used in -01, noted as 1.84A 3 2 3A/3B
100 VRMS (-100 VDC) Used in -00, 40 mA Used in -01, 31 mA 3 2 3A/3B
6.3 VAC (MV 6DJ8) Used in -00 Used in -01 3 2 3A/3B
330 VRMS (Floating Supply) Used in -00 Used in -01 3 2 3A/3B
20 VRMS (X100 Filaments) Used in -00 Not used in –01 T310 3 2 3A/3B
Floating power supply Used in both; drives Square Wave MV Used in both; drives Square Wave MV 4 3 [s/b 4]