The Tektronix Type P plug-in is a step response calibrator [[introduced in | The Tektronix Type P plug-in is a step response calibrator [[introduced in 1959]] for [[500-series scopes]]. | ||
It applies a step signal to the vertical input (plug-in connector pins 1 and 3) of the scope. | It applies a step signal to the vertical input (plug-in connector pins 1 and 3) of the scope. | ||
The step is generated by a [[mercury switch]] in the Type P and it has a 4 nanosecond risetime. | The step is generated by a [[mercury switch]] in the Type P and it has a 4 nanosecond risetime. |
Revision as of 17:25, 30 September 2010
The Tektronix Type P plug-in is a step response calibrator introduced in 1959 for 500-series scopes. It applies a step signal to the vertical input (plug-in connector pins 1 and 3) of the scope. The step is generated by a mercury switch in the Type P and it has a 4 nanosecond risetime. The Type P is designed to simulate a Type K plug-in being driven by a Type 107 pulse generator. In this sense, it is designed to act as a standard, not as an ideal square pulse source. Why is this preferable to calibrating the mainframe using a square pulse? Would the high-frequency components of a square pulse cause problems?
Type P was the only new plugin for 1959, unless you count the upgrade from Type 53/54C to Type CA. It was dropped after 1963.