Я4С-97: Difference between revisions
Jump to navigation
Jump to search
Chrisjones (talk | contribs) (Created page with "{{Plugin Sidebar 2 | title=Я4С-97 | summary=Digital multimeter | image=Я4С-97_front.jpg | caption=Я4С-97 front panel | series=Soviet 7000-series clones| introduced=...") |
Chrisjones (talk | contribs) No edit summary |
||
Line 39: | Line 39: | ||
Я4С-97_switch_detail.jpg | Switch wiring detail | Я4С-97_switch_detail.jpg | Switch wiring detail | ||
Я4С-97_temperature_readout.jpg | Temperature readout | Я4С-97_temperature_readout.jpg | Temperature readout | ||
Я4С-97_voltage_and_resistance_probe.jpg | Voltage and resistance probe | |||
Я4С-97_EHT_probe_.jpg | EHT probe (2kV and 20kV) | |||
Я4С-97_temperature_probe.jpg | Temperature probe | |||
Я4С-97_replacement_temperature_sensor.jpg | Replacement temperature sensor | |||
Я4С-97_probe_connector.jpg | Probe connector | |||
Я4С-97_probe_plugged_in.jpg | Probe plugged in | |||
</gallery> | </gallery> |
Revision as of 03:13, 8 June 2018
The Я4С-97 is a digital multimeter plug-in for Soviet 7000-series clones. It is roughly analogous to the Tek 7D13.
Significant differences to the 7D13 include:
- 2kV and 20kV ranges using an external 100:1 probe
- mode and range switches are separate
- probe connector is a Soviet 8-pin rectangular type
- all modes except current need a special probe
Key Specifications
Voltage ranges | 2V, 20V, 200V, 2kV, 20kV |
---|---|
Current ranges | 2mA, 20mA, 200mA, 2000mA |
Resistance ranges | 200 Ω, 2 kΩ, 20 kΩ, 200 kΩ, 2000 kΩ |
Temperature range | -40 to 120 °C |
The internal architecture of the Я4С-97 seems to be very similar to the 7D13, even down to the 2kHz clock and the transistor-based temperature sensor (which uses a transistor type 2T3316-1 as the probe). However, there is no DAC included for the readout, because the mainframe readout interface is digital, not analogue
Links
Pictures
-
Front
-
Three-quarter view
-
Analogue board
-
Switch wiring detail
-
Temperature readout
-
Voltage and resistance probe
-
EHT probe (2kV and 20kV)
-
Temperature probe
-
Replacement temperature sensor
-
Probe connector
-
Probe plugged in