The Tektronix 3S76 is a dual-trace [[sampling oscilloscope|sampling]] plug-in | The Tektronix 3S76 is a dual-trace [[sampling oscilloscope|sampling]] plug-in | ||
for [[560-series scopes]]. The risetime is rated at less than 0.4ns. Each input | for [[560-series scopes]]. The risetime is rated at less than 0.4ns. Each input | ||
has a trigger takeoff transformer and a 55ns coaxial delay line. The trigger source channel is selectable. | has a trigger takeoff transformer and a 55ns coaxial delay line. The trigger source channel is selectable. | ||
using beam-lead GaAs diodes | Each delay line terminates at that channel's sampling bridge, | ||
The sampling pulse is generated by snap-off diode and a 3cm twisted-pair | which is a four-diode design using beam-lead GaAs diodes. | ||
clipping line. | A [[7586]] nuvistor buffers the output of each sampling bridge. | ||
The sampling pulse is generated by snap-off diode and | |||
a 3cm twisted-pair clipping line. | |||
* [http://bama.edebris.com/download/tek/3s76/3s76.djvu Tektronix 3S76 Manual (DjVu)] | * [http://bama.edebris.com/download/tek/3s76/3s76.djvu Tektronix 3S76 Manual (DjVu)] | ||
* [http://w140.com/tek_3s76.pdf Tektronix 3S76 Manual (PDF)] | * [http://w140.com/tek_3s76.pdf Tektronix 3S76 Manual (PDF)] |
Revision as of 14:05, 18 August 2011
The Tektronix 3S76 is a dual-trace sampling plug-in for 560-series scopes. The risetime is rated at less than 0.4ns. Each input has a trigger takeoff transformer and a 55ns coaxial delay line. The trigger source channel is selectable. Each delay line terminates at that channel's sampling bridge, which is a four-diode design using beam-lead GaAs diodes. A 7586 nuvistor buffers the output of each sampling bridge. The sampling pulse is generated by snap-off diode and a 3cm twisted-pair clipping line.