The '''Tektronix P6106''' is a passive 250 MHz ×10 probe for 1 MΩ inputs. It was available with 1, 2 or 3 meters of probe cable. The 6106 has a coding pin for scope readout ×10. Color coding on probe head and the BNC end sockets indicates how long the cable is. Orange means 2 meters, | The '''Tektronix P6106''' is a passive 250 MHz ×10 probe for 1 MΩ inputs. It was available with 1, 2 or 3 meters of probe cable. The 6106 has a coding pin for scope readout ×10. Color coding on probe head and the BNC end sockets indicates how long the cable is. Blue means 1 meter, Orange means 2 meters, and Red means 3 meters. The P6106 is standard with the [[475]] and [[475A]]. | ||
{{BeginSpecs}} | {{BeginSpecs}} | ||
Line 7: | Line 7: | ||
{{Spec | Compensation range | 15 pF to 24 pF }} | {{Spec | Compensation range | 15 pF to 24 pF }} | ||
{{Spec | Bandwidth | >250 MHz (>150 MHz for 3 meter cable). Using the 1 meter probe with a scope having at least 325 MHz bandwidth results in a system bandwidth of 300 MHz typ. }} | {{Spec | Bandwidth | >250 MHz (>150 MHz for 3 meter cable). Using the 1 meter probe with a scope having at least 325 MHz bandwidth results in a system bandwidth of 300 MHz typ. }} | ||
{{Spec | Input capacitance | 10.5 pF (1 m), | {{Spec | Input capacitance | 10.5 pF (1 m), 13.0 pF (2 m), 15.5 pF (3 m) }} | ||
{{EndSpecs}} | {{EndSpecs}} |
Revision as of 11:48, 24 July 2019
The Tektronix P6106 is a passive 250 MHz ×10 probe for 1 MΩ inputs. It was available with 1, 2 or 3 meters of probe cable. The 6106 has a coding pin for scope readout ×10. Color coding on probe head and the BNC end sockets indicates how long the cable is. Blue means 1 meter, Orange means 2 meters, and Red means 3 meters. The P6106 is standard with the 475 and 475A.
Key Specifications
Attenuation | 10 × ±3% with scope input at 1 MΩ ±2% |
---|---|
Compensation range | 15 pF to 24 pF |
Bandwidth | >250 MHz (>150 MHz for 3 meter cable). Using the 1 meter probe with a scope having at least 325 MHz bandwidth results in a system bandwidth of 300 MHz typ. |
Input capacitance | 10.5 pF (1 m), 13.0 pF (2 m), 15.5 pF (3 m) |
Links
Manuals
Pictures
-
1m variant, blue
-
2m variant, orange