TM5006: Difference between revisions
m (correct typo) |
m (→Specifications) |
||
Line 20: | Line 20: | ||
[[Category:Specifications needed]] ''please add'' | [[Category:Specifications needed]] ''please add'' | ||
Input Voltage 115 V or 230 V nominal (selected with an internal jumper) with options for high, medium or low (100 V 110 V 120 V) or (200 V 220 V 240 V) using a second internal jumper. | Input Voltage 115 V or 230 V nominal (selected with an internal jumper) with options for high, medium or low (100 V 110 V 120 V) or (200 V 220 V 240 V) using a second internal jumper. | ||
Fan Flow Rate is higher in units with the 02 (rack-mount) option | |||
==Links== | ==Links== | ||
* [http://www.barrytech.com/tektronix/tektm500/tektm5006.html TM5006] / [http://www.barrytech.com/tektronix/tektm500/tektm5006a.html TM5006A] @ barrytech.com | * [http://www.barrytech.com/tektronix/tektm500/tektm5006.html TM5006] / [http://www.barrytech.com/tektronix/tektm500/tektm5006a.html TM5006A] @ barrytech.com |
Revision as of 17:27, 19 March 2020
The Tektronix TM5006 is a six-bay mainframe with a GPIB interface for the TM5000 system.
The rightmost compartment (slot 6) can supply high-powered plugins.
The DC rails to the plugins are provided by a switchmode PSU. The supply is not universal input voltage however and must be set with two internal jumper. DC rails are 8V 26V and -26V. The case has a cooling fan which is connected to the PRIMARY of the transformer.
Available options include 02 Rear Inputs and 10 a set of 19-inch rackmount slides.
For option 02 six rear BNC connectors and a 50 pin standard 50 pin female dsub connector will be installed on the rear panel. In addition internal pin headers will be soldered internally. No internal wiring is provided.
The rack-mount kit has different sides compared to the standard model. It is not possible remove the standard carry handle to install a rack-mount kit. The entire side panel must be swapped.
Manuals
Specifications
please add
Input Voltage 115 V or 230 V nominal (selected with an internal jumper) with options for high, medium or low (100 V 110 V 120 V) or (200 V 220 V 240 V) using a second internal jumper. Fan Flow Rate is higher in units with the 02 (rack-mount) option