211: Difference between revisions

From TekWiki
Jump to navigation Jump to search
No edit summary
No edit summary
Line 5: Line 5:


Triggering is done using a [[155-0048-01]].
Triggering is done using a [[155-0048-01]].
The 211 uses a [[155-0047-00]] for X and Y amplification until the final stages,
which use NPN transistors to drive the CRT deflection plates.


* [http://w140.com/Tek211_OpSVC.pdf Tektronix 211 Manual (PDF)]
* [http://w140.com/Tek211_OpSVC.pdf Tektronix 211 Manual (PDF)]

Revision as of 03:58, 11 June 2012

The Tektronix 211 is a 500kHz single-channel miniaturized analog battery-powered oscilloscope.

The probe input first goes through compensated attenuators and then into one gate of Q18, a dual JFET. The drains of the dual JFET drive the inputs of an amplifier IC, U25, part number 155-0057-00.

Triggering is done using a 155-0048-01.

The 211 uses a 155-0047-00 for X and Y amplification until the final stages, which use NPN transistors to drive the CRT deflection plates.