067-1429-00: Difference between revisions

From TekWiki
Jump to navigation Jump to search
No edit summary
No edit summary
 
Line 9: Line 9:


==Internals==
==Internals==
The PCB holds two jumpers: One to select the line voltage, and one to select between dc and ac coupling. Since the output amplifier is an opamp with a series resistor to provide the 75 Ω output resistance the probe adapter is easily modified to 50 Ω output impedance by changing this resistor.  
The PCB holds two jumpers: One to select the line voltage, and one to select between dc and ac coupling. Since the output amplifier is an opamp with a series resistor to provide the 75 Ω output impedance the probe adapter is easily modified to 50 Ω output impedance by changing this resistor.  


==Pictures==
==Pictures==

Latest revision as of 11:07, 16 April 2021

The 067-1429-00 probe adapter is a buffer amplifier intended to be used with a P6109 ×10 probe and a VM700A. It provides a voltage gain of ×10 and an output impedance of 75 Ω.

Key Specifications

Input impedance 1 MΩ //20 pF
Bandwidth >10MHz
Gain ×10 ±2% ( ×1 using passive ×10 probe)
Output impedance 75 Ω

Internals

The PCB holds two jumpers: One to select the line voltage, and one to select between dc and ac coupling. Since the output amplifier is an opamp with a series resistor to provide the 75 Ω output impedance the probe adapter is easily modified to 50 Ω output impedance by changing this resistor.

Pictures