Line 12: Line 12:
In a 516, the [[delay line]] directly drives the  
In a 516, the [[delay line]] directly drives the  
vertical deflection plates of the CRT.
vertical deflection plates of the CRT.
The standard CRT is the [[T55]] with P31 [[phosphor]]. 
It has a post-deflection acceleration voltage of +2335V.
The CRT cathode runs at -1675V.
The HV power supply uses three [[5642]] rectifier tubes:
* V822 for the CRT cathode voltage
* V832 for the CRT control grid voltage
* V842 for the post-deflection voltage


* [http://bama.edebris.com/download/tek/516/516.djvu Tektronix 516 Manual (DjVu)]
* [http://bama.edebris.com/download/tek/516/516.djvu Tektronix 516 Manual (DjVu)]

Revision as of 06:27, 13 May 2013

The Tektronix Type 516 is a monolithic 15MHz dual-trace oscilloscope introduced in 1960. It contains no transistors. The 516 is essentially a dual trace version of the 515. The main difference between the 515 and 516 is the front end. The 515 uses a conventional rotary switch for the input attenuator while the 516 uses turret attenuators. There are also some differences in the vertical amplifier circuitry. The 515 uses a 6AU6 pentode at the front end. The 516 uses a 6DJ8 dual triode at the front end, and in many other places throughout the instrument.

In a 516, the delay line directly drives the vertical deflection plates of the CRT.

The standard CRT is the T55 with P31 phosphor. It has a post-deflection acceleration voltage of +2335V. The CRT cathode runs at -1675V. The HV power supply uses three 5642 rectifier tubes:

  • V822 for the CRT cathode voltage
  • V832 for the CRT control grid voltage
  • V842 for the post-deflection voltage