P6049: Difference between revisions
Jump to navigation
Jump to search
No edit summary |
No edit summary |
||
Line 12: | Line 12: | ||
* [[Media:Tek p6049 fcp may 1968.pdf | Tektronix P6049 Factory Calibration Procedure, May 1968]] (needs OCR) | * [[Media:Tek p6049 fcp may 1968.pdf | Tektronix P6049 Factory Calibration Procedure, May 1968]] (needs OCR) | ||
}} | }} | ||
From the [[Media:1970 Tektronix Catalog.pdf|1970 Catalog]]: The P6049 is a miniature passive probe designed for use with the Sony/Tektronix Type [[323]] portable oscilloscope. The probe is easily compensated for use with any instrument having an input capacitance of 43 pF to 66 pF and an input resistance of 1 MΩ. | From the [[Media:1970 Tektronix Catalog.pdf|1970 Catalog]]: The '''P6049''' is a miniature passive probe designed for use with the Sony/Tektronix Type [[323]] portable oscilloscope. The probe is easily compensated for use with any instrument having an input capacitance of 43 pF to 66 pF and an input resistance of 1 MΩ. | ||
The part number visible on the cable probe end is 010-0222-00. | The part number visible on the cable probe end is 010-0222-00. |
Revision as of 14:15, 12 February 2023
From the 1970 Catalog: The P6049 is a miniature passive probe designed for use with the Sony/Tektronix Type 323 portable oscilloscope. The probe is easily compensated for use with any instrument having an input capacitance of 43 pF to 66 pF and an input resistance of 1 MΩ.
The part number visible on the cable probe end is 010-0222-00.
Key Specifications
Attenuation | 10× |
---|---|
Input Capacitance | 13.5 pF or less |
Risetime | 17 ns or less |
Bandwidth | 21 MHz |
Length | 1.07 m (3.5 ft) |
Voltage Rating | 500 V |
Intended for | Sony/Tektronix Type 323 |