119-2000-0x
The Tektronix 119-2000-0x attenuator module is used in the 11A32 and 11A34 plug-ins. The input is a Tekprobe BNC connector. The attenuator module provides a 50 Ω input termination resistor that can be selected by software/relay, switchable ac or dc coupling and contains two relay actuated 10× attenuators and a 165-2073-00 buffer amplifier providing 50 Ω output impedance.
Pictures
-
Four 119-2000-02 attenuators in an 11A34
-
119-2000-00 attenuator, Peltola cable removed
-
Input connector
-
Relays
-
Relays
-
Relays
-
Relay
-
Relay contacts
-
Amplifier hybrid
-
Amplifier hybrid
-
Amplifier hybrid
-
Connection between hybrids
-
Printed circuit board and flat flex cable
-
Laser trimming
-
Laser trimming
-
Laser trimming
-
Laser trimming
-
Attenuator module in 11A32 input schematic