P6019
The P6019 and P6020 split-core AC current probes were introduced in 1966 together with passive terminations and the Type 134 amplifier.
The probes had no internal frequency compensation components, contrary to their 1969 successor types P6021 and P6022.
Specifications
P6019 passive | P6019 + 134 | P6020 passive | P6020 + 134 | |
---|---|---|---|---|
Sensitivity | 2 mA/mV or 10 mA/mV | 1 mA/Div to 1 A/Div (scope @ 50 mV/Div) | 1 mA/mV or 10 mA/mV | 1 mA/Div to 1 A/Div (scope @ 50 mV/Div) |
Bandwidth (-3 dB) | 60 MHz @ 10 mA/mV | > 40 MHz | 200 MHz @ 10 mA/mV | > 70 MHz |
LF limit (-3 dB) | 450 Hz @ 2 mA/mV, 120 Hz @ 10 mA/mV | < 12 Hz | 6500 Hz @ 1 mA/mV, 775 Hz @ 10 mA/mV | < 50 Hz |
Maximum current | 15 Ap-p | 6 Ap-p |
Links
Manuals
The djvu-file contains a compilation of scans from two editions of the P6019/P6020 manual.