P6460

Revision as of 15:20, 18 August 2024 by Kurt (talk | contribs)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)

The Tektronix P6460 Data Acquisition Probe may be used with DAS9100, 91A24, 91AE24, 1240D1, or 1240D2 Logic Analyzers. It may also be used with and is required for the DP100 Digital Video Probe plug-in used in the TM500 mainframes. It provides 8 data channels plus one qualifier and one clock channel.

Tektronix P6460
Data acquisition probe
Tektronix P6460

Compatible with DAS9200

Produced from (?) to (?)

Manuals


The P6460 uses the P64xx-family 10-wire input lead harnesses with 0.2" connectors. Is also possible to use standard jumper wires with pins, sockets or clips on the other end for connecting inputs.

Key Specifications

Maximum Clock Frequency ?
Data channel Bandwidth 100 MHz
Minimum Pulse Width 4 ns
Input Signal Level -40 V to +10 V above threshold (+30 V for RS232)
Threshold Voltage provided from Logic Analyzer
Input Capacitance 5 pF
Non-destructive Input Voltage Range ±40 V
Maximum Voltage between any two Inputs ±60 V

Links

Pictures