The Tektronix 570 is a curve tracer for tubes. | The Tektronix 570 is a curve tracer for tubes. | ||
The 570 contains five transformers: | |||
* T310: center-tapped isolation transformer for plate sweep | |||
* T340: multitap transformer for heater voltages | |||
* T401: multitap autotransformer for selecting peak plate voltage | |||
* T501: transformer for floating supplies and screen voltage supply | |||
* T620: transformer for HV power oscillator for CRT voltages | |||