585: Difference between revisions

290 bytes added ,  6 June 2020
m
12.6 V supply reference info
m (Fixed typo)
m (12.6 V supply reference info)
Line 189: Line 189:
A transistor-based regulator supplies a +12.6 V heater voltage to the plug-in.
A transistor-based regulator supplies a +12.6 V heater voltage to the plug-in.


A [[delay relay|6N045 delay relay]] controls a multi-contact relay to switch supply voltages on only after the tubes are warmed up.   
A [[delay relay|6NO45 delay relay]] controls a multi-contact relay to switch supply voltages on only after the tubes are warmed up.   
When the main relay engages, the delay relay is cut out so it will be ready to delay again even after a quick interrupt in power input.
When the main relay engages, the delay relay is cut out so it will be ready to delay again even after a quick interrupt in power input.
12.6 V power supply regulation is referenced from +100V regulated output.  Since +100V is not available during the warm-up period, an unregulated +100 V (~+180 V) is fed as the reference to 12.6 V power supply during warmup period. This is cut out by the multi-contact relay post warmup.


The 585 contains a 53°C (128°F) [[thermal cutoff]].
The 585 contains a 53°C (128°F) [[thermal cutoff]].
1,563

edits