2245

From TekWiki
Revision as of 16:58, 7 March 2021 by Kurt (talk | contribs)
Jump to navigation Jump to search
Manuals – Specifications – Links – Pictures


The Tektronix 2245 is a 100 MHz four-channel analog oscilloscope. Channels 1-2 are fully-functional, whereas 3-4 are limited in both deflection factor and coupling, as they are intended mainly for digital and trigger signals.

The 2245 includes features like AUTO SETUP which automatically adjusts vertical, horizontal, and triggering and display controls to provide a stable, triggered display of the waveform in seconds; Dual Time base with Delayed Sweep; Cursor Time/Voltage Measurements; On-Screen Scale Factor Readouts.

Key Specifications

Bandwidth 100 MHz
Deflection CH 1, CH 2: 2 mV/div to 5 V/div in 1-2-5 seq; CH 3, CH 4: 0.1 V/div and 0.5 V/div, all ±2%; BW Limit: 20 MHz ±15%
Vertical Operating Modes CH1,2,3,4, CH2 Invert, Add, Alt, Chop (625 kHz)
Input Impedance 1 MΩ ±1.0% // 20 pF ±1 pF
Maximum Input Voltage 400 V (DC + peak AC) or 800 V (p-p ac at ≤ 10 kHz)
Sweep Speeds A Time Base: 0.5 s/div to 20 ns/div in 1-2-5 seq; B Time Base: 5 ms/div to 20 ns/div in 1-2-5 seq (×10 magnifier to 2 ns/div)
Trigger DC, Noise Reject, HF Reject, LF Reject, AC, TV Line, TV Field
Trigger Modes A Mode: Auto Level, Auto, Norm, TV Line, TV Field, Single Seq. B Mode: Runs After Delay, Auto Level, Norm, TV Line (From A Source)
Trigger Source A & B Vert, CH1, 2, 3, 4, Line
Cursors Time, Volts
Interface Ext Counter/Timer Base Input connector; Ext Z-Axis Input connector
Probes Two P6109 100 MHz ×10 probes, BNC connector with a readout pin
Power 100 W max, 90 − 250 VAC, 48 − 445 Hz

Repair Information

Links

Backup Battery in Tek 2245A

Pictures