The '''Tektronix 013-0055-00 Plug-In Extension''' is used for calibrating and repairing  
The '''Tektronix 013-0055-00 Plug-In Extension''' is used for calibrating and repairing  
Tektronix 530, 540, 550, and 580 series oscilloscopes as well as their plug-ins..
Tektronix [[500-series scopes|530, 540, 550]], and [[585|580]] series oscilloscopes as well as their plug-ins.
   
   
This particular extender is optimized for the 580 series, which has its pin-out flipped 180° over earlier 5xx series.   
The 013-0055-00 extender is optimized for [[580-series scopes]], which has the plug-in pin-out flipped 180° over earlier 5xx series.   
 
Pins 8,9,11,14,16 are connected via 93 Ω coax; these pins are signal and trigger lines on the 580 series,  
Pins 8,9,11,14,16 are connected via 93 Ω coax; these pins are signal and trigger lines on the 580 series,  
but are mostly power pins on the earlier series.  
but are mostly power pins on the earlier series.  


* [[Media:061-888.pdf|013-055 Datasheet (PDF, needs OCR)]]
* [[Media:061-888.pdf|013-055 Datasheet (April 1963, OCR)]]
* [[Media:061-0888-00.pdf|013-0055-00 Datasheet (August 1965 Revision, OCR)]]


<gallery>
<gallery>

Latest revision as of 16:57, 9 March 2024

The Tektronix 013-0055-00 Plug-In Extension is used for calibrating and repairing Tektronix 530, 540, 550, and 580 series oscilloscopes as well as their plug-ins.

The 013-0055-00 extender is optimized for 580-series scopes, which has the plug-in pin-out flipped 180° over earlier 5xx series.

Pins 8,9,11,14,16 are connected via 93 Ω coax; these pins are signal and trigger lines on the 580 series, but are mostly power pins on the earlier series.