31,822
edits
David Wise (talk | contribs) m (correct discontinuation year based on 1965 and 1966 catalogs) |
No edit summary |
||
(16 intermediate revisions by 4 users not shown) | |||
Line 10: | Line 10: | ||
* [http://w140.com/mmm/tek-531-541.pdf Tektronix 531/541 Manual (PDF)] | * [http://w140.com/mmm/tek-531-541.pdf Tektronix 531/541 Manual (PDF)] | ||
* [http://w140.com/tek_541a.pdf Tektronix 541A Manual (PDF)] | * [http://w140.com/tek_541a.pdf Tektronix 541A Manual (PDF)] | ||
* [http://w140.com/tek_fcp/tek_541_fac_cal.pdf Tektronix 541 Factory Calibration Procedure (PDF)] | |||
* [http://w140.com/tek_fcp/tek_541a_fac_cal.pdf Tektronix 541A Factory Calibration Procedure (PDF)] | <!-- * [http://w140.com/tek_fcp/tek_541_fac_cal.pdf Tektronix 541 Factory Calibration Procedure (PDF)] --> | ||
* [http://w140.com/tek_balancing_545_vert.pdf Balancing the 540-Series Vertical Amplifier (PDF)] | * [[Media:tek_541_fcp.pdf|Tektronix 541 Factory Calibration Procedure (PDF, OCR)]] | ||
* [http://w140.com/tek_fcp/tek_adjust_540_vert_delay.pdf How to Adjust the Vertical Amplifier and Delay Line of a 540-Series Oscilloscope (PDF)] | |||
<!-- * [http://w140.com/tek_fcp/tek_541a_fac_cal.pdf Tektronix 541A Factory Calibration Procedure (PDF)] --> | |||
* [[Media:tek_541a_fcp.pdf|Tektronix 541A Factory Calibration Procedure (PDF, OCR)]] | |||
<!-- * [http://w140.com/tek_balancing_545_vert.pdf Balancing the 540-Series Vertical Amplifier (PDF)] --> | |||
* [[Media:tek_balancing_545_vertical.pdf|Balancing the 540-Series Vertical Amplifier (PDF, OCR)]] | |||
<!-- * [http://w140.com/tek_fcp/tek_adjust_540_vert_delay.pdf How to Adjust the Vertical Amplifier and Delay Line of a 540-Series Oscilloscope (PDF)] --> | |||
* [[Media:tek_adjust_540_vertical.pdf|How to Adjust the Vertical Amplifier and Delay Line of a 540-Series Oscilloscope (PDF, OCR)]] | |||
* [[Media:Tek 500-series modification summary.pdf|Modification Summary for 541 and Similar Models (PDF scan from faded printout)]] | |||
}} | }} | ||
The '''Tektronix Type 541''' is a 30 MHz* oscilloscope that accepts [[letter-series and 1-series plug-ins]]. | The '''Tektronix Type 541''' is a 30 MHz* oscilloscope that accepts [[letter-series and 1-series plug-ins]]. | ||
Line 30: | Line 39: | ||
The 541's CRT is part number [[154-098]], also known as the T54. | The 541's CRT is part number [[154-098]], also known as the T54. | ||
The standard [[phosphor]] is P2. The 541A uses the [[T65]] CRT. | The standard [[phosphor]] is P2. The 541A uses the [[T65]] CRT. | ||
There is a rackmount version, Type RM41. | |||
There is also a 541-S7 version, which has single-sweep mode. | There is also a 541-S7 version, which has single-sweep mode. | ||
A new probe, the [[P410|P400 Series]], was created for the 541/545, because the 10 MHz [[P510|P510A]] rings on fast signals. | |||
==Specifications== | ==Specifications== | ||
Line 45: | Line 58: | ||
Tek 541 5100 left.jpg|541 left internal | Tek 541 5100 left.jpg|541 left internal | ||
Tek 541 5100 right.jpg|541 right internal | Tek 541 5100 right.jpg|541 right internal | ||
Tek 541a trace.jpg|541A trace | |||
Tek 541a trace2.jpg|541A trace | |||