The Type 544 is a 50MHz scope with one timebase.
{{Oscilloscope Sidebar|
   
title=Tektronix 544|
The 544 (at least the early ones) uses the same  
image=T tek scope 544 front.jpg|
[[tunnel diodes|tunnel diode]] triggering circuit  
caption=Tektronix 544, front view (with [[1A1]] plug-in) |
as is used in early [[547]]  
introduced=1964 |
(tunnel diode in the collector load of a PNP differential amplifier).  
discontinued=1973 |
summary=50 MHz oscilloscope|
manuals=
* [http://bama.edebris.com/download/tek/544/544.djvu Tektronix 544 Manual (DjVu)]
* [http://w140.com/tek_544.pdf Tektronix 544 Manual (PDF)]
<!-- * [[Media:Tek 547 544 546 technical instruction and training.pdf|Tektronix 547, 546, and 544 Technical Instruction and Training (PDF, needs OCR)]] -->
* [http://w140.com/Hi-speed_recorder.pdf General Electric Report from 1968 Discussing Tek 544 Mod 108G (PDF)]
 
* [[Media:070-418.pdf|Tektronix 544 Manual (PDF, OCR, bad-OCR)]]
* [[Media:Tek_547_544_546_tech_instr_and_training.pdf|Tektronix 547, 546, and 544 Technical Instruction and Training (PDF, OCR)]]
* [[Media:GE_report_1968.pdf|General Electric Report from 1968 Discussing Tek 544 Mod 108G (PDF, OCR, bad-OCR)]]
* [[Media:Tek 544 fcp dec 1968.pdf|Tektronix 544 Factory Calibration Procedure, December 1968 (PDF, needs OCR)]]
}}
 
The '''Tektronix Type 544''' is a 50 MHz scope [[introduced in 1964]]. 
 
It has one timebase with several horizontal magnifier modes (×2, ×5, ×10, ×20, ×50, and ×100).
To make horizontal magnification usable, the 544 has a vernier horizontal position control in addition to the regular horizontal position control.  
The fastest calibrated sweep is 10 ns/div.
Some magnification modes provide sweeps faster than 10 ns/div, but in those modes the horizontal scale is not calibrated, and a lamp on the front panel lights up to remind the operator of that.
 
The 544 (at least the early ones) uses the same [[tunnel diodes|tunnel diode]] triggering circuit  
as is used in early [[547]] (tunnel diode in the collector load of a PNP differential amplifier).  
 
There is also a rackmount version, the RM544.
 
A factory modification, MOD 108G, was available that increased the accelerating voltage to 24 kV.
The 1968 catalog lists an RM544 Mod 720 which has a direct-access plug-in and has 1 ns risetime (equiv. 350 MHz).
 
The vertical amplifier and low voltage power supply of the 544 are the same as those of the [[546]] and [[547]]. 
The 544 uses the [[154-0478-00]] CRT which is also used by the [[543|543B]], [[545|545B]], [[546]], and [[547]].
 
The project lead for the development of the Tektronix 544, [[546]], and [[547]] was [[Bob Rullman]].
 
{{MissingSpecs}}
 
==Pictures==
 
<gallery>
Tek 544 cl.jpg
T tek scope 544 front.jpg|544 Front view
T tek scope 544 left.jpg|544 Left Internal
T tek scope 544 right.jpg|544 Right Internal
Tek 544.jpg      | '''544''' with [[G|Type G]] plug-in, front view
Tek rm544.jpg  | '''RM544''' with [[1A1]] plug-in, front view
</gallery>
 


A factory modification, MOD 108G,
was available that increased the accelerating voltage to 24kv. 
The 1968 catalog lists an RM544 Mod 720
which has a direct-access plug-in and has 1ns risetime.


The vertical amplifier and low voltage power supply of the 544
are the same as those of the [[546]] and [[547]]. 
The 544 uses the [[154-0478-00]] CRT.


* [http://bama.edebris.com/download/tek/544/544.djvu Tektronix 544 Manual (DjVu)]
[[Category:500 series scopes]]