K125 coil must be grounded to close relay and turn on K115 and the rest of the machine.
K125 coil must be grounded to close relay and turn on K115 and the rest of the machine.


K125 coil is controlled by Q588 of the Very/Horz Amplifier (Schematic <6>).
K125 coil is controlled by Q588 of the Vert/Horz Amplifier (Schematic <6>).


Pulled Q588 (TEK p/n 151-0302-00), put it in the 576 Curve Tracer, it tests as a Diode.   