==wavy trace ==
==Wavy trace ==
:'''Symptom:''' wavy trace
:'''Symptom:''' Wavy trace
:'''Root cause:''' C786 (100µF 25V) has high internal resistor (ESR ~ 20 ohms). -12.6 v regulator ciruit is oscillating
:'''Root cause:''' C786 (100µF 25V) has high internal resistor (ESR ~ 20 ohms). +12.6 v regulator ciruit is oscillating
:'''Solution:''' Replacing of  electrolytic capacitor C786 with new part.