84: Difference between revisions

75 bytes added ,  30 December 2011
no edit summary
No edit summary
No edit summary
Line 1: Line 1:
The Tektronix Type 84 is a calibration fixture plug-in for [[580-series scopes]].
The Tektronix Type 84 is a calibration fixture plug-in for [[580-series scopes]].
It was renamed the 067-0523-00 during production.  The Type 84 provides
It was renamed the 067-0523-00 during production.  The Type 84 provides a
a calibrated amplitude signal for adjusting gain, a fast-rise voltage step
calibrated amplitude signal for adjusting gain, a fast-rise voltage step
for adjusting the impulse response of the vertical amplifiers in the scope,
for adjusting the impulse response of the vertical amplifiers in the scope,
and load resistors to test the power supply of the scope.  The fast-rise
and load resistors to test the power supply of the scope.  The fast-rise
pulses are specified to have a repetition rate of 550 to 750 pulses per
pulses are produced by a [[mercury switch]] with part number [[260-0282-02]]
and are specified to have a repetition rate of 550 to 750 pulses per
second, with a rise time that is "considerably less than the response time
second, with a rise time that is "considerably less than the response time
of the vertical amplifier in a 580-series oscilloscope."   
of the vertical amplifier in a 580-series oscilloscope."