Lavoie LA-265A: Difference between revisions

no edit summary
No edit summary
No edit summary
 
(4 intermediate revisions by one other user not shown)
Line 1: Line 1:
{{Oscilloscope Sidebar|
{{Oscilloscope Sidebar
title=Lavoie LA-265A |
|manufacturer=Lavoie
image=LA265A front.JPG |
|model=LA-265A  
caption=Lavoie LA265A with [[Lavoie LA-265-CA]] Plug-in |
|image=LA265A front.JPG  
introduced=(?) |
|caption=Lavoie LA265A with [[Lavoie LA-265-CA]] Plug-in  
discontinued=(?) |
|introduced=(?)  
summary=33 MHz oscilloscope |
|discontinued=(?)  
manuals=
|summary=33 MHz oscilloscope  
* [http://w140.com/LA265A.pdf Lavoie LA-265-A Manual (PDF)]
|designers=
|series=500-series scopes
|manuals=
* [[Media:Lavoie LA265A Manual.pdf|Lavoie LA-265-A Manual]]
}}
}}
The '''Lavoie LA-265A''' is a 33 MHz scope that takes  
The '''Lavoie LA-265A''' is a 33 MHz scope that takes [[letter-series and 1-series plug-ins]].   
[[letter-series and 1-series plug-ins]].  It is an unauthorized clone of a  
It is an [[unauthorized clone]] of a [[545|Tektronix 545A]] made for a defense contract by [[Lavoie Laboratories]].
[[545|Tektronix 545A]] made for a defense contract by [[Lavoie Laboratories]].


It has two timebases, which allows delayed triggering.   
It has two timebases, which allows delayed triggering.   
{{MissingSpecs}}


==Internals==
==Internals==
Line 19: Line 23:
The high-voltage circuit is not identical to that of the Tektronix [[545|545A]].
The high-voltage circuit is not identical to that of the Tektronix [[545|545A]].
Neon lamps are used to stabilize the high voltage in brightness circuit.
Neon lamps are used to stabilize the high voltage in brightness circuit.
However, the neon lamp stabilizer is often faulty - the
However, the neon lamp stabilizer is often faulty - the lamps aged too fast, with the result that the trace flickers.
lamps aged too fast, with the result that the trace flickers.


=== Mechanical difference to 545 ===
=== Mechanical difference to 545 ===
The mains transformer is potted.
The mains transformer is potted.
Unlike Tektronix instruments of the same era, which require  
Unlike Tektronix instruments of the same era, which require [[silver-bearing solder]], ordinary solder is fine for working on the Lavoie, because its terminal strips have tin-plated steel inserts.
silver-bearing solder, ordinary solder is fine for working on the Lavoie.
This is because the terminal strips in the Lavoie have tin-plated steel inserts.


==Links==
==Links==
* [http://www.radiomuseum.org/forum/lavoie_la_265a_a_superb_tek_clone.html LA-265A, a superb Tek clone] (radiomuseum.org forum)
* [https://www.radiomuseum.org/forum/lavoie_la_265a_a_superb_tek_clone.html LA-265A, a superb Tek clone] (radiomuseum.org forum)
* [http://www.radiomuseum.org/r/lavoie_oscilloscope_la_265_ala26.html radiomuseum.org page for LA-265A]
* [https://www.radiomuseum.org/r/lavoie_oscilloscope_la_265_ala26.html radiomuseum.org page for LA-265A]


==Pictures==