P6015: Difference between revisions

From TekWiki
Jump to navigation Jump to search
mNo edit summary
No edit summary
 
(5 intermediate revisions by 2 users not shown)
Line 7: Line 7:
|for=1 MΩ scope inputs
|for=1 MΩ scope inputs
|introduced=1963
|introduced=1963
|discontinued=(?)
|discontinued=1990
|manuals=
|manuals=
* [[Media:070-0373-01.pdf|P6015 Manual 070-0373-01]] (C 1963)
* [[Media:070-0373-01.pdf|P6015 manual 070-0373-01 (1963)]]
* [[Media:070-0373-02.pdf|P6015 Manual 070-0373-02]] (Rev. 1985)
* [[Media:070-0373-02.pdf|P6015 manual 070-0373-02 (1985)]]
* [[Media:070-0373-02 rev 1990.pdf|P6015 Manual 070-0373-02]] (Rev. 1990)
* [[Media:070-0373-02 rev 1990.pdf|P6015 manual 070-0373-02 (1990)]]
* [[Media:070-8223-02.pdf|P6015A Manual 070-8223-02]]
 
* [[Media:070-8223-04.pdf|P6015A Manual 070-8223-04]] (with schematics)
* [[Media:070-8223-05.pdf|P6015A Manual 070-8223-05]]
* [[Media:Tek_p6007_p6009_p6015_cat.pdf|P6007 P6009 P6015 Catalog Description]]
* [[Media:Tek_p6007_p6009_p6015_cat.pdf|P6007 P6009 P6015 Catalog Description]]
* [[Media:51W-8217-2.pdf|P6015A Product Brochure]]
}}
}}
The '''Tektronix P6015''' is a 1000× high-voltage probe usable up to 20 kV (40 kV peak pulse).   
The '''Tektronix P6015''' is a 1000× high-voltage probe usable up to 20 kV (40 kV peak pulse).   


It can be operated with or without dielectric filling but without this filling, the maximum voltage is reduced to 13 kV (18 kV peak), similar to the [[P6013]] predecessor model.<br />The original filling material, [[wikipedia: 1,2-Dichlorotetrafluoroethane|Freon-114 aka Fluorocarbon 114 (R-114, CFC-114)]], is no longer available due to its [[wikipedia:Montreal Protocol|ozone-depleting properties]]. The CFC-free '''P6015A''' successor, introduced in 1991, uses a silicone based replacement.
It can be operated with or without dielectric filling but without this filling, the maximum voltage is reduced to 13 kV (18 kV peak), similar to the [[P6013]] predecessor model.
The original filling material, [[wikipedia: 1,2-Dichlorotetrafluoroethane|Freon-114 aka Fluorocarbon 114 (R-114, CFC-114)]], is no longer available due to its [[wikipedia:Montreal Protocol|ozone-depleting properties]]. For this reason, it was replaced by the [[P6015A]] [[introduced in 1991|in 1991]], which uses a silicone based replacement.


The P6015 has a compensating circuit at the scope end of the cable with multiple adjustable RC constants.
The P6015 has a compensating circuit at the scope end of the cable with multiple adjustable RC constants, which was available with [[PL-259]] or [[BNC]] plugs on the scope side (termination box part numbers 015-039/015-0039-00 and 015-049/015-0049-00, respectively).


{{BeginSpecs}}
{{BeginSpecs}}
Line 38: Line 36:
==Links==
==Links==
* [[Patent US 3256484A|US Patent 3,256,484; ''High voltage test probe containing a part gas, part liquid dielectric fluid under pressure and having a transparent housing section for viewing the presence of the liquid therein'']].  Paul V Terry, 1962.
* [[Patent US 3256484A|US Patent 3,256,484; ''High voltage test probe containing a part gas, part liquid dielectric fluid under pressure and having a transparent housing section for viewing the presence of the liquid therein'']].  Paul V Terry, 1962.
* [https://www.amplifier.cd/Test_Equipment/Tektronix/Tektronix_other/P6015.html P6015A @ amplifier.cd]
* [http://www.barrytech.com/tektronix/probes/tekp6015.html P6015 @ barrytech.com]
* [http://www.barrytech.com/tektronix/probes/tekp6015.html P6015 @ barrytech.com]


==Pictures==
==Pictures==
<gallery>
<gallery>
Tek P6015 box.jpg | Tektronix P6015 in box
Tek P6015 box.jpg           | Tektronix P6015 in box
Tek P6015 box closed.jpg
Tek_P6015_1.jpg
Tek_P6015_1.jpg
Tek_P6015_2.jpg
Tek_P6015_2.jpg
Line 49: Line 47:
Tek_P6015_4.jpg
Tek_P6015_4.jpg
P6015 BW.png
P6015 BW.png
Tek p6015 schem.png
Tek p6015 schem.png         | schematic <br> old version
Tek P6015 derating.jpg      | Derating curves
Tek P6015 derating.jpg      | Derating curves
P6015_Freon_Can.jpg | Can of Freon Dielectric Fluid
P6015_Freon_Can.jpg         | Can of Freon Dielectric Fluid
Tek P6015 term box.jpg      | Termination box
Tek P6015 term box.jpg      | Termination box <br> new version
</gallery>
</gallery>


[[Category:1 MΩ Oscilloscope probes]]
[[Category:1 MΩ Oscilloscope probes]]
[[Category:High voltage oscilloscope probes]]
[[Category:High voltage oscilloscope probes]]

Latest revision as of 03:03, 21 October 2023

Tektronix P6015
20(40) kV, ×1000 Passive Probe
P6015

Compatible with 1 MΩ scope inputs

Produced from 1963 to 1990

Manuals


Manuals – Specifications – Links – Pictures

The Tektronix P6015 is a 1000× high-voltage probe usable up to 20 kV (40 kV peak pulse).

It can be operated with or without dielectric filling but without this filling, the maximum voltage is reduced to 13 kV (18 kV peak), similar to the P6013 predecessor model. The original filling material, Freon-114 aka Fluorocarbon 114 (R-114, CFC-114), is no longer available due to its ozone-depleting properties. For this reason, it was replaced by the P6015A in 1991, which uses a silicone based replacement.

The P6015 has a compensating circuit at the scope end of the cable with multiple adjustable RC constants, which was available with PL-259 or BNC plugs on the scope side (termination box part numbers 015-039/015-0039-00 and 015-049/015-0049-00, respectively).

Key Specifications

Bandwidth 75 MHz (10' cable), 25 MHz (25' cable)
Risetime 4.67 ns (10' cable), 14 ns (25' cable)
Attenuation 1000×
Input impedance 100 MΩ // 3 pF
Compensation range 15-50 pF
Max. input voltage
  • With dielectric filling: 20 kV DC or RMS to 100 kHz, pulse up to 40 kV (10%, < 0.1s)
  • Without dielectric filling: 13 kV DC or RMS to 500 kHz, pulse up to 18 kV (10%, < 0.1s)