The 560 and 561 were short-lived. Both were replaced by the 561A, which offered  
The 560 and 561 were short-lived. Both were replaced by the 561A, which offered  
several performance improvements, within less than a year.
several performance improvements, within less than a year.
==Power Supply==
The 560 has a power supply that is similar to the [[503]]'s power supply.
Mains power first passes through transformer T601,
which produces unregulated AC heater current and 170 Vrms for the second part of the power supply. 
The second part is a regulated power oscillator operating at 25 kHz, using transformer T620. 
The secondary outputs of T620 are simply rectified and filtered, producing -12 VDC, +125 VDC, -100 VDC,
and -3400 VDC.
All regulation is performed by controlling the grid voltage on V620, the power oscillator tube.