Line 51: Line 51:
Mains power first passes through transformer T601,  
Mains power first passes through transformer T601,  
which produces unregulated AC heater current and 170 Vrms for the second part of the power supply.   
which produces unregulated AC heater current and 170 Vrms for the second part of the power supply.   
The second part is a regulated power oscillator operating at 25 kHz, using transformer T620.   
The second part is a regulated Armstrong power oscillator operating at 25 kHz, using transformer T620.   
The secondary outputs of T620 are simply rectified and filtered, producing -12 VDC, +125 VDC, -100 VDC,  
The secondary outputs of T620 are simply rectified and filtered, producing -12 VDC, +125 VDC, -100 VDC,  
and -3400 VDC.
and -3400 VDC.
All regulation is performed by controlling the grid voltage on V620, the power oscillator tube.
All regulation is performed by controlling the screen grid voltage on V620, the power oscillator tube.


In principle, the design used in the 560, which resembles a modern SMPS supply,  