Line 14: Line 14:
}}
}}
The '''Tektronix 4S2''' is a two-channel [[sampling oscilloscope|sampling]] vertical plug-in for the [[661]].   
The '''Tektronix 4S2''' is a two-channel [[sampling oscilloscope|sampling]] vertical plug-in for the [[661]].   
Signals enter the 4S2 through [[GR-874 connector]]s on the front panel. Unlike the [[4S1]], the 4S2's signal path does not contain a [[delay line]] between the input connector and the sampler.  This has the advantage of maintaining higher pulse fidelity and thus higher bandwidth.  It has the disadvantage of making it impossible to see the leading edge of the triggering event unless a pre-trigger is used.   
Signals enter the 4S2 through [[GR-874 connector]]s on the front panel.  
Unlike the [[4S1]], the 4S2's signal path does not contain a [[delay line]] between the input connector and the sampler.   
This has the advantage of maintaining higher pulse fidelity and thus higher bandwidth.   
It has the disadvantage of making it impossible to see the leading edge of the triggering event unless a pre-trigger is used.   


The 4S2 uses a four-diode sampling bridge.  The 4S2A uses a two-diode sampling bridge.   
The 4S2 uses a four-diode sampling bridge.  The 4S2A uses a two-diode sampling bridge.   
This design change is discussed in the 4S2A Engineering Spec document linked below.
This design change is discussed in the 4S2A Engineering Spec document linked below.
The 4S2 does not provide trigger pick-off. The 4S2A provides trigger pick-off.