31,919
edits
No edit summary |
No edit summary |
||
Line 13: | Line 13: | ||
The S-3 sampling head is a plug-in head for use with the | The S-3 sampling head is a plug-in head for use with the | ||
7000 series sampling plug-ins or with the Type [[3S2]], [[3S5]], or [[3S6]] samplers. | 7000 series sampling plug-ins or with the Type [[3S2]], [[3S5]], or [[3S6]] samplers. | ||
The plug-in includes a permanently attached 1× probe with the sampling bridge enclosed in the probe. | The plug-in includes a permanently attached 1× probe with the sampling bridge enclosed in the probe. | ||
Optional 10× or 100× attenuator tips are available. | |||
==Specifications== | ==Specifications== | ||
Line 30: | Line 31: | ||
== Differences between S-3 and S-3A == | == Differences between S-3 and S-3A == | ||
The S-3A sampling head has a 10× improvement in baseline shift due to cable flexing. All other specifications are identical to the ordinary S-3. The major differences in design involves the gate board in the box part of the probe, but some changes are also made to the circuits in the body of the probe. | The S-3A sampling head has a 10× improvement in baseline shift due to cable flexing. | ||
All other specifications are identical to the ordinary S-3. | |||
The major differences in design involves the gate board in the box part of the probe, | |||
but some changes are also made to the circuits in the body of the probe. | |||
== Difference between the S-3 and the P6038 == | == Difference between the S-3 and the P6038 == | ||
The S-3 probe contains a compensated attenuator before the sampling bridge. | The S-3 probe contains a compensated attenuator before the sampling bridge. | ||
The S-3 probe has a JFET buffer between the holding cap and the probe cable. | The [[P6038]] does not. | ||
The S-3 probe has a JFET buffer between the holding cap and the probe cable. | |||
The P6038 does not. | |||
Both use the [[152-0368-00]] sampling bridge. | Both use the [[152-0368-00]] sampling bridge. | ||
Line 42: | Line 48: | ||
==Pictures== | ==Pictures== | ||
<gallery> | <gallery> | ||
S3_frontend.png | |||
S3a attenuator.jpg|S-3A attenuator | |||
S3a box front.jpg|Front | |||
S3a probe external1.jpg|S-3A probe | |||
S3a probe internal1.jpg|S-3A probe internal | |||
S3a probe internal2.jpg|S-3A probe internal | |||
S3a strobe board.jpg|S-3A strobe board | |||
S3a probe_internal_bothsides.jpg|S-3A probe both sides | |||
Tek s3 probe sample bridge.jpg|S-3 probe sampling bridge | |||
Tek s3 sample bridge2.jpg|S-3 probe sampling bridge | |||
</gallery> | </gallery> | ||
[[Category:7000 and 3S series sampling heads]] | [[Category:7000 and 3S series sampling heads]] |