==Specifications== | |||
* Deflection factor: 0.05 v/cm to 50 V/div DC-coupled, 0.005 v/cm to 50 V/div AC-coupled | |||
* Signal inputs: Two signal inputs with more than 60-dB isolation | |||
* Step attenuator: 12 calibrated steps are provided: 0.005, 0.01, 0.02, 0.05, 0.1, 0.2, 0.5, 1, 2, 5, 10, and 20 V/div | |||
* Accuracy: Within ±3% of indicated deflection in calibrated position | |||
* Maximum input voltage: 600 v (dc plus peak ac) | |||
* Risetime: 18 nanoseconds in a [[545]] | |||
* Frequency response: DC to 20 MHz in a [[545]] | |||
Note: Full frequency response is available with deflection sensitivity between 0.05 and 20v/cm. | |||
In more sensitive positions, the input is DC-coupled and slightly slower. | |||