32,959
edits
No edit summary |
No edit summary |
||
Line 17: | Line 17: | ||
* Pin 7: -250V, regulated | * Pin 7: -250V, regulated | ||
* Pin 8: +180V, unregulated | * Pin 8: +180V, unregulated | ||
The 517 makes extensive use of the [[distributed amplifier]] concept. The vertical signal path is | |||
as follows: | |||
* Gain Stage 1: single-ended, six sections, distributed, [[6AK5]] tubes | |||
* Gain Stage 2: single-ended, six sections, distributed, [[6AK5]] tubes | |||
* Gain Stage 3: single-ended, seven sections, distributed, [[6AK5]] tubes | |||
* Signal Delay: 51 feet of RG63U 125-ohm coaxial cable | |||
* Phase Splitter: single-ended in, differential out, three sections, distributed, [[6CB6]] tubes | |||
* Gain Stage 4: differential, six sections, distributed, [[6CB6]] tubes | |||
* Gain Stage 5: differential, twelve sections, distributed, [[6CB6]] tubes | |||
The 517 uses 24kV of acceleration voltage on the CRT. This is generated by the Type 420 High Voltage | |||
Power Supply subsystem in the 517. It uses a 1.8kHz oscillator to produce the high voltage, unlike | |||
other Tek scopes which use HV oscillators in the ultrasonic range. | |||
* [http://w140.com/MILSPEC_High_Speed_Scope.pdf Final Report on Tektronix MILSPEC High Speed Scope] | * [http://w140.com/MILSPEC_High_Speed_Scope.pdf Final Report on Tektronix MILSPEC High Speed Scope] | ||
* [http://w140.com/tek_517_calibration.pdf Tektronix 517 Calibration Guide] | * [http://w140.com/tek_517_calibration.pdf Tektronix 517 Calibration Guide] | ||
* [http://w140.com/tek_517_517a.pdf Manual | * [http://w140.com/tek_517_early.pdf Early 517 Manual (PDF)] | ||
* [http://w140.com/tek_517_517a.pdf Later Manual Covering the 517 and 517A (PDF)] | |||
<gallery> | <gallery> |